WARNING
WARNING DANGER
WARNING
Propane Fire Table Owners Manual
!
!
!
! For outdoor use only.
If you smell gas: Shut off gas to the appliance. Extinguish any open flame. If odor continues, keep away from the appliance and immediately call your gas supplier or fire department.
Do not store or use gasoline or other flammable liquids in the vicinity of this or any other appliance. An LP-cylinder not connected for use should not be stored in the vicinity of this or any other appliance.
Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operation and maintenance instructions thoroughly before installing or servicing this equipment.
170822FT-171212
2
TABLE OF CONTENTS Important Safety Information
Gas Dangers and Warnings
Parts List
Assembly Instructions
Pre-Use Instructions
Lighting Instructions
Care and Cleaning
Spider and Insect Warning
Tips & Troubleshooting
Technical Parts List
Warranty
3
5
6
7
9
10
11
12
13
15
16
DANGER
SPECIFICATIONS
!
CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor.
Using it in an enclosed space can kill you.
Never use this appliance in an enclosed space such as a camper, tent, car or home.
Check and update Specs
Verify Page numbers
Product Name Ledgestone Rectangle
Model No. CT0003LP
Rated Heat Output 65,000 BTUs/hr
Type of Gas Propane (LP)
Gas Supply 20 lb LP-Gas Cylinder
3
IMPORTANT SAFETY INFORMATION Installation notes
General Warnings
Minimum Clearance from unit to combustible materials: 48 (121.9 cm) from all sides and back. Do not place this fire table under any overhead structure or vegetation. Do not place on or above combustible surfaces.
Save these instructions for future reference. If you are assembling this unit for someone else, give this manual to them to read and save for future reference.
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.
Installation and service must be performed by a qualified service agency or gas supplier. Real Flame recommends using professionals who are certified in the U.S. by the National Fireplace Institute (NFI) as NFI Gas Specialists.
The normal LP inlet pressure for this appliance is 11.0 W.C. (2.74 kPa), maximum inlet pressure is 13.0 W.C. (3.23 kPa), minimum inlet pressure is 8 W.C. (1.99 kPa).
If this fire table has been converted to natural gas, the normal inlet pressure for this appliance is 7.0 W.C. (1.74 kPa), maximum inlet pressure is 10.5 W.C. (2.61kPa), minimum inlet pressure is 3.5 W.C. (0.87 kPa).
Do not remove the feet from the fire table.
Do not place the fire table on anything that blocks or seals the gap between the table and the ground.
Do not permanently secure the fire table in any way or to any surfaces.
Do not bury the hose. You must be able to visually inspect the hose for damage before each use.
Do not coil or hide the hose under the fire table. The hose could be damaged if it touches hot surfaces.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when in the area of the fire table.
Clothing or other flammable materials should not be hung from the fire table or placed on or near the appliance.
Any guard or other protective device removed for servicing the fire table must be replaced prior to operating the appliance.
Installation and repair should be done by a qualified service person. The fire table should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required as necessary. It is imperative that the control compartment, burners, and circulating air passageways of the appliance are kept clean.
Do not store or use gasoline or other flammable vapors or liquids within 25 feet ( 7.62 m) of this or any other appliance.
Do not store combustible materials in the fire table enclosure. This includes LP tanks. If the fire table is designed to use a hidden LP tank, the LP tank should be properly secured in the designated tank holder under the table. Do not store extra LP tanks under the fire table.
Be sure to protect the hose and its components from any hot surfaces. It is dangerous to allow the hose to come into contact with any hot surface.
If using your fire table with a LP tank, the tank should never be operated or stored on its side or up- side-down.
4
IMPORTANT SAFETY INFORMATION General Warnings (Cont.)
Set-Up Warnings
In-Use Warnings
Keep all parts of the fire table clean including the burner and hose assembly. For more information on cleaning your fire table please refer to the Care and Cleaning section of this manual.
Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water.
Do not use this fire table for cooking.
Do not pour water into the fire table.
Do not attempt to move or store this fire table until all parts are cool.
Always shut off the gas supply at the source and disconnect the hose when the fire table is not in use.
Any alteration of this outdoor fire table that is not specifically directed in the owners manual will void the manufacturers warranty. This includes the use of unapproved filler materials.
Prior to each operation, check the hose assembly for evidence of excessive abrasion, wear or damage. Use a hand-held mirror, if necessary, to see hose sections located below the unit.
If the hose assembly is damaged, cracked, or cut, it must be replaced before using the fire table. The hose assembly must be replaced with a hose assembly specified by Real Flame. Please call us at 1-800-654-1704 for assistance.
Place the hose out of the pathways where people may trip over it. Do not place the hose in areas where it may be accidentally damaged.
Before each use, examine the burner and its components for dirt and debris. If cleaning is required, use a pipe brush and soapy water solution. Also examine the area around the burner. Any dirt or foreign material such as spider webs, nests, leaves, etc., should be removed. If it is evident that the burner is damaged, the fire table must not be used, and the burner assembly must be replaced. Please contact Real Flame at 1-800-654-1704 for support.
Do not burn solid fuels such as wood, charcoal briquettes, lump charcoal, manufactured logs, drift wood, trash, leaves, paper, cardboard, plywood, painted, stained or pressure-treated wood and other materials in this fire table.
NEVER LEAVE this fire table unattended when in use.
The use of alcohol, prescription or non-prescription drugs may impair your ability to safely operate this fire table.
Always use in accordance with all applicable local, state and national codes. Contact your local fire department for details on outdoor burning.
Do not use in windy conditions. Winds above 10 mph may cause the flame to extinguish.
Some surfaces of this fire table may become hot during use. Be careful and do not touch surfaces until the unit has cooled.
5
GAS DANGERS AND WARNINGS
LP Gas Warnings
LP Characteristics LP gas is flammable, explosive under pressure, heavier than air and settles in pools in low areas.
Pooled gas may ignite causing a fire or explosion which could cause property damage, injury or death. In its natural state, propane has no odor. For your safety, a scent has been added. Contact with propane could burn your skin.
LP Tank Information LP gas cylinders should be filled only by a certified LP gas dealer. Never use a propane cylinder with a damaged body, valve, collar or footing. Dented or rusted propane cylinders may be hazardous and should be checked by your propane gas
supplier. The LP gas supply tank must be constructed and marked in accordance with the Specifications for
LP gas tanks of the U.S. Department of Transportation (DOT) or the National Standard of Canada, CAN/CSA-B339, LP gas tanks, Spheres and Tubes for the Transportation of Dangerous Goods; and Commission.
LP gas tanks must be arranged for vapor withdrawal. LP gas tanks must have a listed overfilling prevention device (OPD) and a QCCI or Type I (CGA810) LP
gas tank connection. The LP gas cylinder must contain a shutoff valve as specified in the Standard for Compressed Gas
Cylinder Valve Outlet and Inlet Connection, ANSI/CGA-V-1-1977, CSA B96. Never attempt to attach this appliance to the self-contained LP gas system of a camper trailer, motor
home or house. Hand-turn the manual gas control valve on your LP tank. Never use tools. If the valve will not turn by
hand, do not try to repair it. Call a certified gas technician. The use of force or any attempt at amateur repair may cause a fire or explosion.
LP Tank Storage and Safety Cylinders must be stored upright and outdoors in a well-ventilated area out of reach of children. Never store an LP cylinder in any enclosed area such as a shed or garage. Leaking gas could build up
in these areas and may result in an explosion. Do not store LP gas tanks near any source of flame or ignition. Never store your LP gas tank in direct sunlight or where temperatures can reach 125F or higher. Never keep a filled LP gas tank in a hot car or car trunk. Heat will cause the gas pressure to increase,
which may open the relief valve and allow gas to escape. Place dust cap on valve outlet whenever the LP gas tank is not in use. Install only the type of dust cap
on the LP gas tank valve outlet that is provided with the LP gas tank valve. Other types of caps or plugs may result in leakage of propane.
The LP gas tank should not be dropped or handled roughly.
LP gas is flammable and hazardous if handled improperly. Become aware of its characteristics before using any LP gas product. Failure to understand and follow these warnings or any directions and warnings provided by your LP supplier may result in property damage, injury or death.
DANGER! A LP cylinder should never be placed on its side. Doing so may cause liquid propane to leak. This could cause a fast build-up of propane gas and could lead to property damage, injury or death.
In-Use Warnings (Cont.) Do not attempt to disconnect the gas supply from the fire table when the unit is in use.
Do not sit on the fire table.
6
PARTS LIST
1 2 3
ITEM NUMBER QUANTITY
4 5 6 7
00023109S
Ledgestone Fire Table N/A 1
LP Hose and Regulator 100190000 1
Feet 06000003 4
Glass Beads 00036204 2
Tank Seat 100260000 1
Protective Cover 00030006 1
Natural Gas Conversion Kit 00023109S 1
1
2
3
4
5
6
7
7
ASSEMBLY INSTRUCTIONS 1.) Install the AAA battery as shown in the diagram below
2.) Place (lava rock, glass filler, other) by hand. Do not dump the bag into the burner area, or directly onto the burner to avoid clogging the burner with dust. Position the filler material across the burn area to a level 1 above the burner. Make sure that you do not block the igniter housing with filler to ensure proper ignition and operation.
If using glass filler Real Flame suggests placing a layer of lava rock down first around the burner then adding glass on top of that to improve airflow to the burner.
Lava Rock and Glass Filler Warning 1. Do not overfill the burner area with rock or glass filler; use only the specified amount. The depth of the filler should not be more than one inch above the burner tube. Only Real Flame filler products have been certified and tested for safe use with this Real Flame fire table. Using other filler material may result in increased popping and cracking or increased carbon monoxide emissions. 2. Do not light or use this fire table if the filler is wet. Ensure filler is completely dry before lighting. Intense heat can cause wet filler to explode and hit someone causing injury. 3. Keep away from the fire table for at least 20 minutes during initial start-up as filler could retain moisture from manufacturing and shipping.
+ -
Igniter box
8
ASSEMBLY INSTRUCTIONS
4.) Connect the LP Gas Tank Before connection, be sure there is no debris caught in the collar of the gas cylinder, the regulator valve or the burner and burner ports.
Connect the gas line to the tank by turning the connection knob clockwise. Hand tighten only.
To disconnect the LP tank, make sure the valve on the LP gas tank is completely closed.
Disconnect the connection knob by turning it counter- clockwise until it is detached from the valve.
WARNING! Place the LP tank 56 away from the fire table and locate the hose away from pathways or places where it could become damaged.
Watch your step while moving between the tank and the fire table. Be careful not to trip on the hose.
3.) Place the tank seat on the ground and place a 20 lb. propane tank into the designated area in the center. Once the tank is level and steady, tighten down the screw on the side of the tank seat to secure the tank in place.
60
9
PRE-USE INSTRUCTIONS WARNING!
Before using this fire table, make sure you have read, understand, and are following all information provided in this manual. Failure to follow these instructions could cause property damage, serious injury or death.
Make a leak check solution by mixing one part dish-washing soap with three parts water in a spray bottle.
Make sure that the control knob on the fire table is in the OFF position, then connect your fire table to a LP gas tank and turn the tanks valve on.
Spray leak solution on the valve connections, paying particular attention to the areas indicated in the diagrams below by arrows.
If bubbles appear, close the tank valve, disconnect the tank, and inspect all connections making sure threads are clear of debris. Reconnect the LP tank and re-test. If you continue to see bubbles, turn the LP gas tank off, disconnect it and call Real Flame at 1-800-654-1704 for assistance.
If no bubbles appear after one minute, wipe away excess leak solution and proceed to the next step.
Checking for Leaks
Pay close attention to the areas indicated by the arrows
10
LIGHTING INSTRUCTIONS Using the Igniter 1. Read and understand all operating instructions before lighting. 2. Before beginning, make sure the control knob is in the OFF position. 3. Connect your propane cylinder (see previous pages). 4. Slowly open the valve on your LP cylinder. 5. Prepare to ignite your fire table by placing one hand on the control
knob and one hand on the ignition button(as seen in diagram on the right). DO NOT lean over any part of the burner, and verify that the area around the burner is free of hazards.
6. Push and hold the igniter, you should hear a clicking sound. 7. While holding the igniter depressed with one hand, use your other
hand to push in and turn the control knob to the LIGHT position. 8. Once the burner ignites, release the igniter button, but continue to keep the control knob
pushed in for 15-30 seconds. 9. WARNING: If ignition does not occur in 30 seconds, turn the control knob to the OFF
position and turn the gas off at its source. Make sure there is no source of ignition around the fire table and wait at least five minutes until the gas has cleared to repeat the lighting procedure. Failure to do so could result in a large flashback of pooled gas, causing property damage or injury.
10. After successfully lighting the table, release the control knob and turn it to the LOW setting. Observe the flame and make sure that all the burn ports are lit.
11. Adjust the flame to the desired height using the control knob.
1. Turn the control knob to the OFF position. 2. Close the valve on the LP tank to shut-off gas flow.
Shut-off Instructions
Push Control Knob In
Flame Height
8-14 20.3-35.5 cm
1 1
CARE AND CLEANING Inspecting Your Fire Table
General Care and Cleaning
Storage
Your fire table should be inspected regularly to ensure that it is safe to use and to extend the life of its parts.
To inspect your fire table follow these steps. 1. Make sure all parts are securely fastened in place. If a part moves when touched, check its
connection points to see if they are loose. 2. Check all connections for leaks using the leak check method described in the Check for Leaks
section of this manual. 3. Check the ignition system by pushing the igniter button and verifying that a spark is being
generated in the igniter housing. 4. Visually check all components for any signs of damage, rust, or excessive wear. 5. If damage or leaks of any kind are found, DO NOT operate the fire table until the proper repairs
have been made.
After repeated use, a slight discoloration or weathering of the fire table finish may occur. Your fire table should be cleaned regularly to ensure safe use and extend its life.
General Cleaning Make a cleaning solution using a mild soap mixed with water. Use a soft cloth to wipe down exterior surfaces and rinse with clean water. Never use oven cleaners or abrasive solvents as these will damage the fire table.
Burner The burner should be kept clean to ensure proper operation. Clogged burn ports may be cleared with a paper clip or pin. Debris in the burner can be cleaned using compressed air or a pipe brush.
Soot After use it is possible for soot to develop on some surfaces, this soot deposit will usually come off with water and mild soap.
1. Turn the gas supply off at the tank. Remove the tank and store it in a cool, dry location, outside and away from children.
2. Secure all loose filler material or parts. 3. Remove the battery from the ignition box. 4. Cover your fire table when it will not be in use. Covering the table will help to protect the
internal components from dirt and debris, prevent water from pooling on the surfaces and prevent the finish from fading and discoloring.
5. Store the fire table in a cool, dry location away from children and pets.
WARNING
WARNING
!
!
DO NOT inspect, clean, move or store your fire table until the flames are COMPLETELY out and all parts are cool to the touch.
DO NOT tamper with this appliance. This is dangerous and will void the warranty.
Repairs and modifications must be approved by Real Flame and completed by a professional gas technician.
This fire table has been tested and certified by a third party certification agency based on its specific and unique parts. Installing any other parts will void both the certification and the warranty. For approved replacement parts, contact Real Flame at: 1-800-654-1704
12
SPIDER AND INSECT WARNING Spiders or other insects may build webs or nests in your fire table burner tube which can obstruct or block the flow of gas.
Some of the gas may back up in the burn tube and cause a flashback (a fire in the burn tube or underneath the fire table) which could result in personal injury or property damage. Check and clean the burn tube periodically using a pipe cleaner brush (as shown below) available at any hardware store.
Example of a typical burn tube Your exact burner may vary
Burn Tube Insect Nest
Air Intake
Run Pipe Cleaner through burn tube
Possible Spider Nest or Debris
Example of pipe cleaning brush available at local hardware stores.
13
TIPS & TROUBLESHOOTING If the fire table will not ignite
CORRECT INCORRECT
If the fire table will not stay lit
1. Make sure that the battery is not dead and that it is installed correctly, with the positive (+) side facing out.
1. Make sure that the igniter housing is unobstructed. Clear away any filler material or debris on the housing and make sure there is nothing between the igniter pin and the thermocouple
If the ignition system is working correctly, you should hear a clicking sound while the igniter button is pushed and you should see a spark inside the igniter housing. If you do not see the spark or hear a clicking sound, please check the following.
If the fire table lights, but will not stay lit, or remains lit only for a brief time, please check the following.
2. If you still do not hear a clicking sound or see a spark in the igniter housing, look under the fire table and make sure that the electrode wire is correctly inserted into the back of the electronic ignition box. While inspecting the electrode wire, make sure that it is not cut or broken in any place. If the wire has been damaged contact Real Flame at 1-800-654-1704 for a replacement.
3.) If you hear clicking but cannot see a spark in the igniter housing, look under the table. Check between the electrode wire connection at the back of the electronic ignition and the connection point at the burn pan. If you see a spark anywhere under the table, look for damage to the wire or an incomplete connection at that point. If the wire has been damaged contact Real Flame at 1-800-654-1704 for a replacement.
+ -
Igniter Housing
Burner Tube
Do not block opening
Back of Electronic
Ignition
Electrode Wire
14
TIPS & TROUBLESHOOTING If the fire table will not stay lit (Continued)
Other Common Problems
Make sure that the thermocouple and electrode are correctly positioned.
The igniter housing has been removed from the illustration to the right to better show positioning; however, you should be able to look through the openings of the igniter housing to verify this without removing it.
Thermocouple - The thermocouple tip should be located close to the burner, aligned with a burn port so that flames contact it directly. Make sure the flames are making contact with the thermocouple tip.
Electrode - The electrode is where the spark is generated to ignite your fire table. Make sure that you can see this sparking when the igniter button is pushed.
Damaged Thermocouple If the igniter housing and the thermocouple tip are clear of debris and the flame is clearly contacting the tip of the thermocouple, but the fire table will still not stay lit, the thermocouple may be damaged. Look beneath the table and find the copper thermocouple wire coming out of the back of the valve. Examine the length of it for any signs of damage. Sharp bends, kinks or damage can cause the thermocouple to not function correctly. If you find damage to the thermocouple contact Real Flame at 1-800-654-1704 for a replacement.
Clogged or Obstructed Burner It is common for bugs, especially spiders, to make webs or nests inside of burner tubes. If it seems like you are getting low or no gas flow, visually check all openings in the burner for signs of clogs. If you see anything clogging the burner try using compressed air to remove the debris.
Out of Gas Be sure that your tank is not empty. Low tanks can result in lower flames.
Cold Temperatures Cold temperatures outside may result in lower tank pressures causing the flames to be lower. Do not use your fire table in extreme temperature conditions. Allow the temperature of your tank to rise and as the pressure in the tank increases the flame size will increase. NEVER heat your tank; allow it to warm up naturally.
High Winds Your fire table is designed to operate in winds up to 10 mph. High winds may cause the flame to blow out. Do not operate your fire table in high wind conditions.
Thermocouple Make sure flame is contacting this.
Electrode You should see this spark when pushing the igniter button.
Igniter Housing removed for visibility
If you continue to have problems with your fire table please contact Real Flame customer service at : 1-800-654-1704
15
TECHNICAL PARTS LIST Burn Tube 100390002Thermocouple
100210000
Igniter Electrode and Igniter Ground xxxxxxxx
Orifice Spud 100370002
Bellows (CSST) 100370003
Valve 100370000
LP Hose and Regulator 100190000
Control Knob 10040U000
Igniter Housing N/A
Electronic Ignition 100220000
Burn Pan N/A
Natural Gas Conversion Kit
00023109S
Fire Table Body N/A
Adjustable Feet 06000003
16
WARRANTY & RETURN POLICIES Warranty Real Flame Company warrants Real Flame fireplaces and accessories to be free from defects in parts under normal use and service for a period of 1 year from the date of purchase and defective from finish issues for a period of 1 years from the date of purchase. In the event of such defects Real Flame will, at its option, replace the defective product or refund the purchase price. The foregoing is the exclusive remedy and Real Flame disclaims all other warranties, including any implied warranty of merchantability or fitness for a particular purpose. In addition, Real Flame will not be responsible for consequential damages in excess of the purchase price of the product on which such liability is based.
Return Policy You may return your purchase within 90 days of receipt. No refunds will be issued for incomplete or unauthorized returns. All returned products must be 100% complete, adequately packaged in original packaging and in resalable condition. Products that have been assembled or modified will not be eligible for return. All items must be returned in their entirety, meaning all items included must be returned together. No returns or exchanges on discontinued items. Please begin the return process by contacting the store or company where you bought your Real Flame item.
Replacement Parts In the event that an item has been lost or damaged, either by the manufacturer or in shipping, you may request a replacement. Replacement parts are not available for all units and only given at Real Flames discretion. We will assess any damage and find a solution, which could include shipping you a replacement. No replacements are available for discontinued items or repackaged (open box) products. Please call Real Flame Customer Service at 800-654-1704 for replacement parts before returning the damaged item. Please have the following information (which can be found in your instruction manual) ready before you call Customer Service. Model Number of Item 4-8 digit Part Number Lot Code Number Shipping Address A picture of the damaged item may be requested. Pictures should be sent to [email protected]
Incorrect Order Received If you received something other than what you ordered, please contact Real Flame Customer Service at 800-654-1704 within 48 hours of receiving the item. Please refer to www.Realflame.com for our complete return guidelines and policies.
Please refer to www.Realflame.com for our complete return guidelines and policies.
Real Flame 7800 Northwestern Ave.
Racine, WI 53406
Customer Service: 1-800-654-1704 in USA Service la clientle: 1-800-363-6443 in Canada
17
CT0003LP Ledgestone
AVERTISSEMENT
DANGER
MANUEL DU PROPRITAIRE DE TABLE FEU
!
!
Pour usage extrieur uniquement.
170822FT-171212
Si vous sentez du gaz: Arrtez le gaz lappareil. teignez toute flamme nue. Si lodeur persiste, loignez- vous de lappareil et appelez immdiatement votre fournisseur de gaz ou votre service des incendies.
AVERTISSEMENT
AVERTISSEMENT
!
! Ne stockez pas ou nutiliser pas de lessence ou dautres liquides inflammables proximit de cet appareil ou de tout autre appareil. Une bouteille de GPL non connect pour lutilisation ne doit pas tre stocke proximit de cet appareil ou dun autre appareil.
Linstallation, le rglage, laltration, le service ou lentretien inadquat peuvent causer des blessures ou des dommages matriels. Lisez attentivement les instructions dinstallation, dutilisation et de maintenance avant dinstaller ou dentretenir cet quipement.
18
Informations Importantes sur la Scurit
Dangers et Avertissements sur les Gaz
Liste des Pices
Instructions dAssemblage
Instructions de Pr-utilisation
Instructions dclairage
Entretien et Nettoyage
Avertissement sur les Araigne et les Insectes
Conseils et Dpannage
Liste des Pices Techniques
Garantie
3
5
6
7
9
10
11
12
13
15
16
DANGER!
CO Warning must be 12 pt bold
Check and update Specs
Verify Page numbers
Nom du Produit Ledgestone Rectangle
No. Du Modle CT0003LP
Puissance nominale 65,000 BTUs/hr
Type de Gaz Propane (GPL)
Approvisionnement en Gaz Bouteille de GPL de 20 lb
SOMMAIRE
RISQUE DU MONOXYDE DE CARBONE Cet appareil peut produire du monoxyde de carbone qui na pas dodeur.
Lutiliser dans un espace ferm peut vous tuer.
Nutilisez jamais cet appareil dans un espace ferm tel quun camping-car, une tente, une voiture ou une maison.
CARACTRISTIQUES
19
Notes dinstallation
Avertissements Gnraux
Distance Minimale de lunit aux matriaux combustibles: 48 (121,9 cm) de tous les cts et de larrire. Ne placez pas cette table feu sous aucune structure arienne ou vgtarienne. Ne la placez pas sur ou au-dessus des surfaces combustibles.
Gardez ces instructions pour rfrence ultrieure. Si vous assemblez cette unit pour quelquun dautre, donnez-leur ce manuel pour lire et sauvegarder pour rfrence ultrieure.
Si les informations contenues dans ce manuel ne sont pas suivies exactement, un incendie ou une explosion peut entraner des dommages matriels, des blessures corporelles ou le dcs.
Linstallation et lentretien doivent tre effectus par une agence de service qualifie ou un fournisseur de gaz. Real Flame recommande dutiliser des professionnels certifis aux tats-Unis par le National Fireplace Institute (NFI) en tant que Spcialistes NFI du Gaz.
La pression dentre GPL normale pour cet appareil est de 11.0 W.C. (2,74 kPa), la pression dentre maximale est de 13,0 W.C. (3,23 kPa), la pression dentre minimale est de 8 W.C. (1,99 kPa).
Si cette table feu a t convertie au gaz naturel, la pression dentre normale pour cet appareil est de 7,0 W.C. (1,74 kPa), la pression dentre maximale est de 10,5 W.C. (2.61kPa), la pression dentre minimale est de 3,5 W.C. (0,87 kPa).
Ne retirez pas les pieds du foyer feu.
Ne placez pas le foyer feu sur tout ce qui bloque ou scelle lespace entre le foyer et le sol. Ne fixez pas de manire permanence le foyer feu de quelque manire que ce soit ou aucune surface.
Nenterrez pas le tuyau. Vous devez pouvoir inspecter visuellement le tuyau avant toute utilisation.
Nenroulez pas ou ne cachez pas le tuyau sous le foyer feu. Le tuyau pourrait tre endommag sil touche des surfaces chaudes.
Les enfants et les adultes doivent tre informs des risques de tempratures de surface leves et doivent rester loigns pour viter les brlures ou que leurs vtements prennent feu.
Les jeunes enfants devraient tre soigneusement surveills dans la zone du foyer feu.
Les vtements ou autres matriaux inflammables ne doivent pas tre accrochs au foyer feu ou placs sur ou proximit de lappareil.
Toute protection ou autre dispositif de protection retir pour lentretien du foyer feu doit tre remplac avant dutiliser lappareil.
Linstallation et la rparation doivent tre effectues par une personne qualifie. Le foyer feu doit tre inspect avant utilisation et au moins une fois par anne par un technicien qualifi. Un nettoyage plus frquent peut tre ncessaire si jug ncessaire. Il est impratif que le compartiment de commande, les brleurs et les passages de circulation dair de lappareil soient maintenus propres.
Nentreposez pas ou nutilisez pas de lessence ou dautres vapeurs ou liquides inflammables moins de 25 pieds (7,62 m) de ce appareil ou de tout autre appareil.
Ne rangez pas de matriaux combustibles dans le botier du foyer feu. Cela comprend les bouteilles de GPL. Si le foyer feu est conu pour utiliser une bouteille de GPL dissimul, la bouteille de GPL doit tre correctement fix dans le porte-bouteille dsign sous le foyer. Ne stockez pas de bouteilles de GPL supplmentaires sous le foyer feu.
Assurez-vous de protger le tuyau et ses composants de toutes surfaces chaudes. Il est dangereux de permettre au tuyau dentrer en contact avec une surface chaude.
Si vous utilisez votre feu avec une bouteille de GPL, la bouteille ne doit jamais tre utilise ou stocke sur son ct ou lorsquelle est renverse.
INFORMATIONS IMPORTANTES SUR LA SCURIT
20
Avertissements Gnraux (Suite)
Avertissements dInstallation
Avertissements en Cours dUtilisation
Gardez toutes les parties du foyer feu propres, y compris le brleur et lassemblage du tuyau. Pour plus dinformations sur le nettoyage de votre table feu, reportez-vous la section Entretien et Nettoyage de ce manuel.
Nutilisez pas cet appareil si une partie a t immerge. Appelez immdiatement un technicien de service qualifi pour inspecter lappareil et remplacer toute partie du systme de contrle et toute commande de gaz qui a t sous leau.
Nutilisez pas cette table feu pour la cuisson.
Ne versez pas deau dans le foyer feu.
Nessayez pas de dplacer ou de ranger cette table feu jusqu ce que toutes les pices soient froides.
Coupez toujours lalimentation en gaz la source et dbranchez le tuyau lorsque le foyer feu nest pas utilis.
Toute modification de ce foyer feu extrieure qui nest pas spcifiquement dirige dans le manuel du propritaire annulera la garantie du fabricant. Cela comprend lutilisation de matriaux de remplissage non approuvs.
Avant chaque opration, vrifiez lassemblage du tuyau pour vous assurer quil ny a pas trop dabrasion, dusure ou de dommage. Utilisez un miroir portatif, si ncessaire, pour voir les sections de tuyau situes sous lappareil.
Si le flexible est endommag, fissur ou coup, il doit tre remplac avant dutiliser le foyer feu. Lensemble de tuyau doit tre remplac par un ensemble de tuyau spcifi par Real Flame. Veuillez nous appeler au 1-800-654-1704 pour obtenir de lassistance.
Placez le tuyau hors des sentiers o les gens peuvent trbucher dessus. Ne placez pas le tuyau dans les endroits o il risque dtre endommag accidentellement.
Avant chaque utilisation, examinez le brleur et ses composants pour dtecter la salet et les dbris. Si le nettoyage est ncessaire, utilisez une brosse tuyau et une solution deau savonneuse. Examinez galement la zone autour du brleur. Toutes salets ou matires trangres telle que les toiles daraignes, les nids, les feuilles, etc., doivent tre enleves. Sil est vident que le brleur est endommag, le foyer feu ne doit pas tre utilis et le brleur doit tre remplac. Veuillez contacter Real Flame au 1-800-654-1704 pour obtenir de lassistance.
Ne brlez pas de combustibles solides comme le bois, les briquettes de charbon de bois, le charbon de bois, les bches fabriques, le bois flott, les dchets, les feuilles, le papier, le carton, le contreplaqu, le bois peint ou trait.
NE LAISSEZ JAMAIS ce foyer feu sans surveillance lorsquil est en cours dutilisation.
Lutilisation dalcool, de mdicaments sur ordonnance ou en vente libre peut nuire votre capacit utiliser ce foyer feu en toute scurit.
Utilisez toujours conformment tous les codes locaux, tatiques et nationaux applicables. Contactez votre service dincendie local pour plus de dtails sur la combustion en plein air.
Ne lutilisez pas dans des conditions venteuses. Les vents suprieurs 10 km/h peuvent teindre la flamme.
Certaines surfaces de ce foyer feu peuvent devenir chaud pendant lutilisation. Faites attention et ne touchez pas les surfaces De lappareil jusqu ce quelles soient refroidies.
INFORMATIONS IMPORTANTES SUR LA SCURIT
21
DANGERS DE GAZ ET AVERTISSEMENTS
Avertissements de GPL
Caractristiques de GPL Le GPL est inflammable, explosif sous pression, plus lourd que lair et se dpose dans les fosses dans
les zones basses. Le gaz combin peut senflammer en provoquant un incendie ou une explosion qui pourrait causer des dommages matriels, des blessures ou la mort.
Dans son tat naturel, le propane na pas dodeur. Pour votre scurit, un parfum a t ajout. Le contact avec du propane pourrait brler votre peau.
Informations sur le rservoir de GPL Les bouteilles de GPL doivent tre remplies uniquement par un distributeur de gaz naturel certifi. Nutilisez jamais une bouteille propane avec un corps endommag, une vanne, un collier ou un pied. Les bouteilles de propane ronges ou rouilles peuvent tre dangereuses et devraient tre vrifies
par votre fournisseur de gaz propane. Le rservoir dalimentation en GPL doit tre construit et marqu conformment aux spcifications
pour les rservoirs de GPL du ministre des Transports des tats-Unis (DOT) ou la Norme Nationale du Canada, CAN/CSA-B339, les rservoirs de GPL, les sphres et les tubes pour le Transport de Marchandises Dangereuses; et la Commission.
Les rservoirs de GPL doivent tre disposs pour le retrait des vapeurs. Les rservoirs de GPL doivent tre munis dun dispositif anti-dbordement (OPD) et dun raccord de
rservoir de gaz propane QCCI ou Type I (CGA810). La bouteille de GPL doit contenir une soupape darrt conforme la norme ANSI/CGA-V-1-1977, CSA
B96, la Norme relative la Sortie de la Vanne et la Tubulure de la Bouteille de Gaz Comprim. Nessayez jamais dattacher cet appareil au systme de GPL dune tente-caravane, dune maison
moteur ou dune maison. Tournez manuellement la vanne manuelle de commande de gaz sur votre rservoir de GPL. Nutilisez jamais
doutils. Si la vanne ne tourne pas la main, nessayez pas de la rparer. Appelez un technicien en gaz certifi. Lutilisation de la force ou toute tentative de rparation damateur peut provoquer un incendie ou une explosion.
Stockage et scurit des bouteilles GPL Les bouteilles doivent tre stocks verticalement et lextrieur dans un endroit bien ventil hors de
porte des enfants. Ne rangez jamais une bouteille de GPL dans une zone ferme telle quun hangar ou un garage. Des
fuites de gaz pourraient saccumuler dans ces zones et entraner une explosion. Ne rangez pas les bouteilles de GPL proximit de toute source de flamme ou dallumage. Ne rangez jamais votre bouteille de GPL la lumire directe du soleil ou lorsque les tempratures
peuvent atteindre 125 F ou plus. Ne gardez jamais une bouteille de GPL remplie dans une voiture chaude ou un coffre de voiture. La
chaleur entranera une augmentation de la pression du gaz, ce qui peut ouvrir la vanne de dcharge et permettre au gaz de schapper.
Placez le cache-poussire sur la sortie de la vanne lorsque la bouteille de GPL nest pas utilis. Installez uniquement le type de capuchon anti-poussire sur la sortie de la vanne de la bouteille de GPL qui est fournie avec la vanne de la bouteille de GPL. Dautres types de capuchons ou de bouchons peuvent entraner une fuite de propane.
La bouteille de GPL ne devrait pas tre retire ou manipule brutalement.
Le GPL est inflammable et dangereux sil nest pas manipul correctement. Prenez conscience de ses caractristiques avant dutiliser un produit de GPL. Le non-respect de ces avertissements ou de ces instructions et de ces avertissements fournis par votre fournisseur de GPL peut entraner des dommages matriels, des blessures ou la mort.
DANGER! Une bouteille de GPL ne doit jamais tre plac sur son ct. Cela pourrait provoquer une fuite de propane liquide. Cela pourrait provoquer une accumulation rapide de gaz propane et pourrait entraner des dommages matriels, des blessures ou la mort.
Avertissements en Cours dUtilisation (Suite) Nessayez pas de dbrancher lalimentation en gaz du foyer gaz lorsque lappareil est utilis. Ne vous asseyez pas sur le foyer feu.
22
LISTE DES PICES
1
2
3
ARTICLE NOMBRE MONTANT
4 5 6 7
00023109S
1
2
3
4
5
6
7
Table de Feu N/A 1
LP Tuyau et el Rgulateur 100190000 1
Pieds 06000003 4
Des Billes de Verre 00036204 2
Sige du rservoir 100260000 1
Couvercle de Protection 00030006 1
Kit de Conversion NG 00023109S 1
23
INSTRUCTIONS DASSEMBLAGE 1.) Installez la pile AAA comme indiqu sur le schma ci-dessous below
2.) Placez (pierre volcanique, fibres de verre, autre) avec la main. Ne jetez pas le sac dans la zone du brleur ou directement sur le brleur pour viter les engorgements du brleur avec de la poussire. Placez le matriau de remplissage dans la zone de combustion jusqu un niveau 1 au-dessus du brleur. Assurez-vous de ne pas bloquer le botier de lallumeur avec le matriau de remplissage pour assurer un allumage et un fonctionnement appropris.
Si vous utilisez des fibres de verre Real Flame suggre de placer une couche de pierre volcanique dabord autour du brleur puis dajouter du verre en plus pour amliorer lcoulement dair vers le brleur.
Avertissement de Fibres de Verre et de Pierre Volcanique 1. Ne remplissez pas trop la zone du brleur avec de la pierre ou des fibres de verre; utilisez uniquement le montant spcifi. La profondeur du rembourrage ne doit pas tre suprieure un pouce au-dessus du tube du brleur. Seuls les produits de remplissage de Real Flame ont t certifis et tests pour une utilisation sre avec ce foyer feu de Real Flame. Lutilisation dun autre matriau de remplissage peut entraner une augmentation des pousses et des craquements ou des missions accrues de monoxyde de carbone. 2. Nallumez pas ou nutilisez pas ce foyer feu si le matriau de remplissage est humide. Assurez-vous que le matriau de remplissage est compltement sec avant lallumage. Une chaleur intense peut provoquer une explosion du matriau de remplissage humide et frapper quelquun lui causant des blessures. 3. Tenez-vous lcart du foyer feu pendant au moins 20 minutes lors du dmarrage initial car le matriau de remplissage pourrait conserver lhumidit de la fabrication et de lexpdition.
Botier de la flamme pilote
+ -
24
4.) Connectez la bouteille de GPL Avant la connexion, assurez-vous quil ny a pas de dbris dans le collier de la bouteille de gaz, la vanne de rgulation ou le brleur et les orifices du brleur.
Connectez la conduite de gaz la bouteille en tournant le bouton de connexion dans le sens des aiguilles dune montre. Serrez la main uniquement.
Pour dbrancher la bouteille de GPL, assurez-vous que la vanne de la bouteille de GPL est compltement ferme.
Dbranchez le bouton de connexion en le tournant dans le sens inverse des aiguilles dune montre jusqu ce quil soit dtach de la vanne.
AVERTISSEMENT! Placez la bouteille de GPL 56 loin du foyer feu et localisez le tuyau lcart des voies ou des endroits o il pourrait tre endommag. Surveillez votre dmarche en vous dplaant entre la bouteille et le foyer feu. Veillez ne pas emmler vos pieds avec le tuyau.
3.) Placez le sige de la bouteille sur le sol et placez une bouteille de propane de 20 lb dans la zone dsigne au centre. Une fois que la bouteille est horizontale et stable, serrez la vis sur le ct du sige de la bouteille pour fixer la bouteille en place.
INSTRUCTIONS DASSEMBLAGE
60
25
INSTRUCTIONS DE PR-UTILISATION
AVERTISSEMENT! Avant dutiliser ce foyer feu, assurez-vous davoir lu, compris et suivi toutes les informations fournies dans ce manuel. Le non-respect de ces instructions pourrait causer des dommages matriels, des blessures graves ou le dcs.
Faites une sol