Dyson Purifier Cool v2 User Manual
![Dyson Purifier Cool manual cover](/images/631b481ec8301c406127d1d5/thumbs/thumb175x175.webp)
![English English](/static/img/blank.webp)
User manual
SV 12
J N
.0 00
00 P
N .0
00 00
0- 00
-0 0
00
.0 0.
00 V
ER SI
O N
N O
.0 1
Contents Assembling your machine Getting started Connecting to the Dyson Link app Connecting to your smart home Power and continuous monitoring Information menu Auto mode Airflow speed and direction Oscillation
Night mode and Sleep timer Changing your HEPA+Carbon filter Resetting your HEPA+Carbon filter life Changing your HEPA and carbon filters Resetting your HEPA and carbon filter life Changing your HEPA+Carbon filters with a catalytic filter Resetting your HEPA+Carbon filter life Looking after your machine
Front view of the Dyson Purifier Cool air purifier fan, showing the amplifier loop and mesh filter cover.
Dyson Purifier Cool
Assembling your machine
Use both hands to lift your machine out of the box, by its base.
Do not lift out by the loop amplifier.
Assemble your machine with the filters that are supplied.
Dyson Purifier Cool Supplied with a HEPA+Carbon filter.
Push your HEPA+Carbon filter into the outer cover and position onto the base. Push firmly until both outer covers click securely into place.
Clik
Clik
Dyson Purifier Cool Supplied with separate HEPA and carbon filters.
Push the carbon filters into place on the machine.
Push the HEPA filter into the outer cover. Put the outer covers into position on the base and push firmly until they both click securely into place.
Clik
Clik
Dyson Purifier Cool Formaldehyde Your machine comes with a permanent catalytic filter and a HEPA+Carbon filter.
Push the catalytic filter into position on the machine.
Push the HEPA+Carbon filter into the outer cover and position on the base. Push firmly until both outer covers click into place.
Clik
Clik
Getting started
Place the remote control on top of the machine with the buttons facing down.
Plug in and switch on.
Standby on/off
Remote control
Standby on/off
Airflow speed
Oscillation on/off
Information menu
Auto mode
Airflow direction
Night mode
Clik
Clik
The air purifier fan with the filter covers open showing a HEPA filter located in the filter covers and a carbon filter. Arrows demonstrate that the carbon filter is fitted directly to the base of the machine and the filter covers will need to be assembled onto the base of the machine.
The air purifier fan with the filter covers open showing a HEPA plus carbon filter located in the filter covers and a catalytic filter. Arrows demonstrate that the catalytic filter is fitted directly to the base of the machine and the filter covers will need to be assembled onto the base of the machine.
An image of the air purifier fan with the remote placed on the top of the loop amplifier and the location of the standby on/off button on the top of the base of the machine.
The layout of the remote control with the power button on the top left, the airflow speed toggle button in the middle left and the oscillation button on the bottom left. On the top right-hand side is the Information menu button, then going downwards is the Auto mode button, Airflow direction and then the Night mode button at the bottom.
The air purifier fan with the filter covers open showing a HEPA plus carbon filter located in the filter covers. Arrows demonstrate that the filter covers will need to be assembled onto the base of the machine.
Connecting to the Dyson Link app
Take full control with the Dyson Link app and access step-by-step setup and support, control how and when your Dyson purifying fan operates, monitor air quality with visual updates and automatically keep up to date with the latest software updates.
Download the Dyson Link app from the App Store or Google Play.
Open the app and follow the on-screen instructions to create a new account.
Apple and the Apple logo are trademarks of Apple Inc., registered in the U.S. and other countries. App Store is a service mark of Apple Inc., registered in the U.S. and other countries. Google Play and the Google Play logo are trademarks of Google Inc.
The Android robot is reproduced or modified from work created and shared by Google and used according to terms described in the Creative Commons 3.0 Attribution License.
Connecting to your smart home
Using Amazon Alexa Ask Alexa to enable the Dyson skill, to control your Dyson purifier or purifier humidifier. And set a routine that automates how your machine works with other devices in your home.
Using Google Assistant Control all of your connected purifiers with Google or set a routine to automate how your machine works with other devices in your home. Just say Hey Google to get started.
Using Siri Connect your Dyson machines to Siri Shortcuts and youll be able to control them with your voice, on your Apple device.
Available on Android stores
Power and continuous monitoring
Standby on/off Press the Standby on/off button on your Dyson purifying fan or remote control to stop your machine. It will continue to monitor the air quality.
Continuous monitoring Continuous monitoring is turned off by default. Once turned on, it will always be active until you turn it off again.
With continuous monitoring turned on, your Dyson purifying fan will gather air quality, temperature and humidity information, which is displayed on the LCD screen and in the Dyson Link app.
Continuous monitoring Press and hold the Auto mode button on the remote control for 5 seconds to turn it on. The LCD screen will indicate when continuous monitoring is on or off.
Wi-Fi Connectivity Wi-Fi is on by default. To turn the Wi-Fi on or off, press and hold the Standby on/off button on your machine for 5 seconds.
Information menu
Press this button to scroll through the information being monitored by your Dyson purifying fan.
Information about air quality, temperature, humidity and filter levels is shown on the LCD screen.
When a particular type of pollutant causes air quality to decrease, a symbol for the pollutant will show on the LCD screen.
Indoor air quality - 12 seconds Monitor the current air quality with a graph showing the last 12 seconds of data.
Particulate matter (PM10) Larger microscopic particles up to 10 microns in size, suspended in the air we breathe. These include dust, mold and pollen.
Nitrogen dioxide and other oxidizing gases These potentially harmful gases are released into the air by combustion, for example, the burning gas when cooking and in vehicle exhaust emissions.
Indoor humidity The amount of water vapour in the air, shown as a percentage.
Formaldehyde (HCHO) A common indoor pollutant. It can be released for many years from furnishings, floorings and glue.
Particulate matter (PM2.5) Microscopic particles up to 2.5 microns in size, suspended in the air we breathe. These include smoke, bacteria and allergens.
Volatile organic compounds VOCs are typically odors that may be potentially harmful. These can be found in cleaning products, paints and furnishings.
Indoor temperature Monitor the ambient temperature to help maintain a comfortable environment.
Filters The remaining filter life is shown on the LCD screen and will indicate when your filters need replacing
Wi-Fi The current status of connection to the Wi-Fi network.
4868 F
4868 F
The remote control with the information button on the top right.
Auto mode
Set your Dyson purifying fan to Auto mode and the on-board sensors will intelligently adjust the settings of the machine according to the air quality.
Air quality: your machine will pause when the target air quality has been reached, switching on again when the air quality levels drop.
Airflow speed: the airflow speed will increase until the target air quality and temperature have been reached.
Airflow speed and direction
Press the Airflow speed button to increase and decrease the airflow speed.
Press the Airflow direction button to change the direction of airflow from front to back.
Change the airflow direction for your personal comfort.
Select the Airflow direction to Fan mode for airflow from the front for purifying and cooling.
Oscillation
Press the Oscillation button to circulate the air around the room and scroll through the oscillation settings from 0 to 350.
Customize your oscillation setting in the Dyson Link app.
Night mode and Sleep timer
In Night mode, your Dyson purifying fan will continue to monitor and respond to changes in air quality, but only using its quietest settings and with its LCD screen dimmed.
Press the Night mode and Sleep timer button to scroll through the timer options.
The remote control with the Auto mode button below the Information button on the right.
The remote control with the Airflow speed toggle button on the left hand side, in the middle. The Airflow direction button is on the right below the Auto mode button.
The remote control with the oscillation button on the bottom left.
The remote control with the Night mode and sleep timer button on the bottom right.
Changing your HEPA+Carbon filter
Before changing your filter, switch off and unplug your Dyson purifying fan.
The remaining filter life is displayed on the screen and will indicate when your non-washable filters need replacing. Press the Information button on your remote or check on the Dyson Link app.
Youll need to reset the filter life on your machine.
Dyson Purifier Cool Supplied with a HEPA+Carbon filter.
To change your HEPA+Carbon filter, push down on the buttons either side of your machine to release the outer cover. Push down on the tabs to remove the filter.
Push the replacement filter into the outer cover and make sure the tabs click into place.
Put the outer covers into position on your machine and push firmly until they both click securely into position.
Plug in and switch your machine, and reset your filter life.
Resetting your HEPA+Carbon filter life
Its important to reset your filter life after you have replaced your filter.
Resetting your HEPA+Carbon filter life Press and hold the Night mode button on your remote control.
The display on your machine will countdown from five, the filter life will be reset and your machine is ready to use.
5 sec
The air purifier fan with the filter covers open showing a HEPA plus carbon filter located in the filter covers. Arrows demonstrate that the filter covers will need to be assembled onto the base of the machine.
Pressing the night mode and sleep timer button on the bottom right of the remote control for 5 seconds.
Changing your HEPA and carbon filters
Before changing your filter, switch off and unplug your Dyson purifying fan.
The remaining filter life is displayed on the screen and will indicate when your non-washable filters need replacing. Press the Information button on your remote or check on the Dyson Link app.
Youll need to reset the filter life on your machine.
Dyson Purifier Cool Supplied with separate HEPA and carbon filters.
To change your HEPA filter, push down on the buttons either side of your machine to release the filter covers. Push down on the tabs to remove the HEPA filter.
Push the replacement filter into the outer cover and make sure the tabs click into place.
To change the carbon filter from your machine, remove the filter from the base of your machine and insert the replacement filter.
Put the outer covers into position on your machine and push firmly until they both click securely into position.
Plug in and switch your machine, and reset your filter life.
Resetting your HEPA and carbon filter life
Its important to reset your filter life after you have replaced your filter.
Resetting your HEPA filter life Press and hold the Night mode button on your remote control.
The display on your machine will countdown from five, the filter life will be reset and your machine is ready to use.
Resetting your carbon filter life Press and hold the Oscillation button on your remote control.
The display on your machine will countdown from five, the filter life will be reset and your machine is ready to use.
5 sec
5 sec
The air purifier fan with the filter covers open showing a HEPA filter located in the filter covers and a carbon filter. Arrows demonstrate that the carbon filter is fitted directly to the base of the machine and the filter covers will need to be assembled onto the base of the machine.
Pressing the Oscillation button on the bottom left of the remote control for 5 seconds.
Pressing the night mode and sleep timer button on the bottom right of the remote control for 5 seconds.
Changing your HEPA+Carbon filters with a catalytic filter
Before changing your filter, switch off and unplug your Dyson purifying fan.
The remaining filter life is displayed on the screen and will indicate when your non-washable filters need replacing. Press the Information button on your remote or check on the Dyson Link app.
Youll need to reset the filter life on your machine.
Dyson Purifier Cool Formaldehyde Your machine comes with a permanent catalytic filter and a HEPA+Carbon filter.
You wont need to change your catalytic filter.
To change your HEPA+Carbon filter, push down on the buttons either side of your machine to release the outer cover. Push down on the tabs to remove the filter.
Push the replacement filter into the outer cover and make sure the tabs click into place.
Put the outer covers into position on your machine and push firmly until they both click securely into position.
Plug in and switch your machine, and reset your filter life.
Resetting your HEPA+Carbon filter life
Its important to reset your filter life after you have replaced your filter.
Resetting your HEPA+Carbon filter life Press and hold the Night mode button on your remote control.
The display on your machine will countdown from five, the filter life will be reset and your machine is ready to use.
5 sec
The air purifier fan with the filter covers open showing a HEPA filter located in the filter covers and a carbon filter. Arrows demonstrate that the carbon filter is fitted directly to the base of the machine and the filter covers will need to be assembled onto the base of the machine.
Pressing the night mode and sleep timer button on the bottom right of the remote control for 5 seconds.
Looking after your machine
To always get the best performance from your Dyson purifying fan, its important to regularly clean it and check for blockages.
Cleaning your machine If your machine is dusty, wipe with a damp lint-free cloth.
Look for blockages in the air inlet holes on the filter and the small aperture inside the loop amplifier.
Use a soft brush to remove dust and debris.
Dont use detergents or polishes to clean your machine.
Error codes If your machine shows an error code, try turning it off and then on again. If this doesnt clear the e-rror code contact Dys