Drayton Motorised - 3 Port Diverter Installation Guide
![Drayton Motorised Valve - 3 Port Diverter Valve manual cover](/images/uZHWQsndxSBgBoVvyXBgAuoI/thumbs/thumb175x175.webp)
To install a Drayton Motorised 3 Port Diverter Valve, first ensure the power is off. Drain the system and remove the old valve if applicable. Mount the new valve in the correct orientation as per the installation manual, connect the wiring according to the schematic provided, and refill the system before testing the valve's operation.
If the valve isn't switching correctly, check for wiring issues or obstructions in the valve mechanism. Ensure the actuator is receiving power and the manual lever isn't stuck. If the problem persists, the actuator or valve motor might need replacement.
To manually override the valve, locate the manual lever on the actuator. Push it to the 'manual' position, which is usually marked on the device. This will open the valve, allowing you to bypass the electronic control temporarily.
Regular maintenance includes checking the valve for leaks, ensuring the actuator is operating smoothly, and inspecting wiring connections for wear. It's also advisable to periodically test the manual override to ensure it functions correctly.
To replace the actuator, turn off the power and remove the existing actuator by unscrewing it from the valve body. Disconnect the wiring and attach the new actuator by aligning it correctly and securing it with screws. Reconnect the wiring as per the provided diagram.
Noise from the valve could be due to air in the system, debris blocking the valve, or a faulty actuator. Bleeding the system to remove air, cleaning out the valve, or replacing the actuator can often resolve the issue.
To test the valve, ensure the system is powered and observe the valve's response to thermostat or timer commands. Check if the valve switches positions as expected and listen for any unusual sounds that might indicate a problem.
Yes, a Drayton 3 Port Diverter Valve can be used with a smart thermostat, provided the thermostat supports the type of valve and is compatible with your heating system. Check the thermostat's installation manual for specific wiring instructions.
If the valve is leaking, inspect the seals and connections for wear or damage. Tighten any loose fittings and replace any faulty seals. If the leak persists, consider replacing the entire valve.
Signs of failure include the valve not switching positions, unusual noises, leaks, or the heating system not responding correctly. Testing the valve and actuator, as well as checking for electrical faults, can help diagnose the problem.