To reset the boiler, press and hold the reset button located on the front panel until the reset light stops flashing. This should take about 5 seconds.
Check if the thermostat is set correctly and ensure the boiler is receiving power. If the issue persists, inspect the pressure gauge to ensure the pressure is between 1 and 1.5 bar.
It is recommended to service your boiler annually to ensure optimal performance and efficiency.
Loud banging noises can be caused by trapped air in the system or a buildup of limescale. Bleed the radiators and consider using a descaling agent.
Locate the filling loop beneath the boiler, then open the valves to allow water to flow into the system until the pressure reaches 1-1.5 bar. Close the valves afterward.
Error code EA indicates an ignition failure. Check the gas supply and ensure there are no obstructions in the flue.
Yes, the Worcester 27i Boiler is compatible with most smart thermostats, but it is recommended to check compatibility with the thermostat manufacturer.
Turn off the heating and use a radiator key to open the bleed valve. Allow air to escape until water begins to leak out, then close the valve tightly.
Regular pressure loss can be due to leaks in the system, faulty expansion vessel, or a malfunctioning pressure relief valve. Inspect the system for visible leaks and consult a technician if necessary.
If you smell gas, immediately turn off the gas supply, ventilate the area, and contact a Gas Safe registered engineer. Do not attempt to fix the issue yourself.