Worcester Heatslave 2 12/18 2013 User Instructions
![Worcester Heatslave 2 12/18 2013 Boiler manual cover](/images/DCHroqGCyJwWcBjzKqBTfyAU/thumbs/thumb175x175.webp)
To reset the Worcester Heatslave 2 12/18 boiler, locate the reset button on the control panel. Press and hold the button for a few seconds until the reset light goes out. This should reset the boiler and clear any fault codes.
First, check if the thermostat setting is correct and ensure there is a demand for hot water. Verify that the boiler is receiving power. If the issue persists, inspect the pressure gauge and ensure it is within the recommended range. Consider checking for any error codes that may indicate specific faults.
It is recommended to service the Worcester Heatslave 2 12/18 boiler annually. Regular servicing helps maintain the efficiency and reliability of the boiler, reducing the risk of breakdowns.
A flashing red light typically indicates a fault within the boiler. Check the control panel for any error codes and refer to the user manual to diagnose the issue. If unsure, contact a qualified technician for further assistance.
To increase the water pressure, locate the filling loop (usually found under the boiler) and open the valves to allow water to enter the system. Monitor the pressure gauge and close the valves once the desired pressure is reached.
A loud banging noise, often referred to as "kettling," may be caused by limescale buildup or trapped air within the system. Consider a power flush for the system and check for any air locks. If the issue persists, consult a professional technician.
The ideal pressure range for the Worcester Heatslave 2 12/18 boiler is typically between 1.0 and 1.5 bar. Regularly check the pressure gauge and ensure it remains within this range for optimal performance.
Yes, the Worcester Heatslave 2 12/18 boiler is compatible with many smart thermostats. Ensure that the smart thermostat you choose is compatible with your boiler model and installed by a qualified technician to avoid any operational issues.
An EA error code indicates a failure to ignite. Check that there is an adequate supply of gas and ensure the condensate pipe is not blocked. Reset the boiler and attempt to restart it. If the error persists, contact a professional technician.
To bleed the radiators, turn off the heating system and wait for the radiators to cool. Use a radiator key to turn the bleed valve counterclockwise, allowing air to escape. Once water begins to flow steadily, close the valve. Repeat this process for each radiator.