Worcester 24i RSF Combi 2000 User Instructions
![Worcester 24i RSF Combi 2000 Boiler manual cover](/images/SvFoRdQvAeLBUSpKMfLvxpkj/thumbs/thumb175x175.webp)
To reset the boiler, locate the reset button which is usually on the front panel. Press and hold the button for a few seconds until the reset light turns off and the boiler restarts. If the issue persists, consult the manual or contact a professional technician.
Check if there is an error code displayed. Ensure the water pressure is adequate (typically between 1-1.5 bar). If the pressure is low, you may need to top up the system. Also, ensure the thermostat is set to the desired temperature. If these steps don't work, consider calling a technician.
Regular maintenance is key. Have your boiler serviced annually by a qualified engineer to ensure it operates efficiently. Bleed radiators regularly, check for leaks, and ensure the system is free from sludge by using a cleaning agent if necessary.
Banging noises can be caused by trapped air, low water pressure, or a build-up of limescale. Bleed the radiators to release any trapped air and check the water pressure. If the problem persists, a power flush may be needed to remove limescale and debris.
The boiler's pressure gauge should read between 1 and 1.5 bar when the system is cold. If the pressure is outside this range, you may need to top up or release water from the system.
Locate the filling loop, which is usually situated beneath the boiler. Attach the filling loop if not already connected, and slowly open the valves until the pressure gauge reads between 1 and 1.5 bar. Close the valves and ensure they are securely tightened.
Yes, but it's advisable to install a water softener or a scale inhibitor to reduce limescale build-up, which can affect the efficiency and lifespan of the boiler. Regular maintenance and descaling are also recommended.
First, check if there is a gas supply issue. If the supply is fine, try relighting the pilot light following the instructions in the user manual. If it continually goes out, there might be a faulty thermocouple or another component issue, requiring professional repair.
It is recommended to service your boiler annually. Regular servicing by a certified engineer ensures safety, efficiency, and longevity of the boiler. It can also help identify potential issues before they become serious problems.
Common error codes include EA (flame not detected) and A1 (low water pressure). Each code indicates a different issue. Refer to the user manual for a full list of error codes and troubleshooting steps, or consult a professional for assistance.