Subaru SGX3500 Parts Manual
![Subaru SGX3500 Generator manual cover](/images/mxGjKgLndozuubaBborNLeik/thumbs/thumb175x175.webp)
To start the Subaru SGX3500 generator, first ensure that the fuel valve is open and the choke is set to the 'start' position. Turn the engine switch to 'ON'. Pull the recoil starter handle gently until resistance is felt, then pull briskly to start the engine. Once started, gradually move the choke to the 'run' position.
The Subaru SGX3500 generator is designed to run on unleaded gasoline with a minimum octane rating of 87. Avoid using fuel with high ethanol content as it may cause operational issues.
Change the oil in the Subaru SGX3500 generator after the first 20 hours of operation, and then every 50 hours thereafter. Use SAE 10W-30 oil for optimal performance.
If the Subaru SGX3500 generator won't start, check that the fuel valve is open and there is enough fuel. Ensure the spark plug is clean and properly connected. Inspect the air filter for clogs and verify that the engine switch is in the 'ON' position.
To store the Subaru SGX3500 generator for an extended period, drain the fuel tank and carburetor. Change the oil and remove the spark plug, adding a few drops of oil into the cylinder and cranking the engine to distribute it. Store the generator in a dry, well-ventilated area.
Check the air filter of the Subaru SGX3500 generator every 25 hours of use. Clean it with compressed air if it's dirty or replace it if it's damaged. A clean air filter is crucial for efficient operation.
To reduce noise from the Subaru SGX3500 generator, use a noise-reducing enclosure or position the generator further away from populated areas. Ensure that the exhaust is directed away from occupied spaces.
If the Subaru SGX3500 generator runs but doesn't produce electricity, check the circuit breaker and reset it if necessary. Inspect the connections for any loose wires and test the outlets for power.
To perform a load test on the Subaru SGX3500 generator, connect a load such as a lamp or appliance to the generator. Start the generator and observe if it powers the load without interruption. This helps ensure the generator is functioning properly.
The recommended spark plug gap for the Subaru SGX3500 generator is 0.028-0.031 inches (0.7-0.8 mm). Make sure the spark plug is clean and properly gapped to ensure efficient engine performance.