Subaru RG2800iS Parts Manual

Subaru RG2800iS Generator manual cover
Pages 38
Year 2004
Language(s)
English en

Subaru RG2800iS Generator Specification

The Subaru RG2800iS Generator is a compact and efficient portable power solution, designed for both residential and recreational use. It features an inverter technology that provides clean and stable power suitable for sensitive electronic devices. This generator is powered by a robust Subaru EX17, 4-stroke, overhead cam gasoline engine, delivering a maximum output of 2800 watts. Its continuous power output is rated at 2500 watts, making it ideal for operating essential appliances and electronics during power outages or outdoor activities.

The RG2800iS is equipped with a fuel-efficient system, offering up to 8 hours of runtime at 50% load on a single fuel tank. It includes a recoil start mechanism, ensuring reliable and easy starting. The generator is designed with user-friendly controls and multiple power outlets, including two 120V AC outlets and one 12V DC outlet, providing versatile connectivity options for various devices.

This model emphasizes portability, featuring a compact design with integrated carrying handles and a noise-reducing enclosure that operates at a quiet noise level, making it suitable for use in noise-sensitive environments. Safety features include circuit breakers and an automatic low oil shutdown to prevent engine damage. The RG2800iS is built with durable materials, ensuring long-lasting performance and reliability. It meets EPA and CARB emissions standards, reflecting Subaru’s commitment to environmental responsibility. Overall, the Subaru RG2800iS Generator is a versatile, reliable, and environmentally conscious power solution, ideal for users seeking a balance of performance, portability, and low noise operation.

Subaru RG2800iS Generator F.A.Q.

How do I start the Subaru RG2800iS generator?

To start the Subaru RG2800iS generator, first ensure that the generator is on a level surface. Check the oil and fuel levels. Turn the fuel valve to the "ON" position. Set the choke lever to the "CLOSE" position if starting cold. Turn the ignition switch to the "ON" position, then pull the recoil starter grip lightly until you feel resistance, and then pull firmly. Once the engine starts, move the choke lever to the "OPEN" position gradually.

What regular maintenance is required for the Subaru RG2800iS generator?

Regular maintenance for the Subaru RG2800iS generator includes checking and changing the oil every 50 hours of operation or every 6 months, cleaning the air filter every 50 hours, and inspecting the spark plug every 100 hours. Ensure all bolts and nuts are tightened properly and check the fuel system for leaks or damage.

What type of oil should be used in the Subaru RG2800iS generator?

The Subaru RG2800iS generator should use SAE 10W-30 oil for general use. If operating in extreme temperatures, refer to the owner's manual for suitable oil types. Always ensure the oil is API Service Category SJ or higher.

How can I troubleshoot if the generator won't start?

If the Subaru RG2800iS generator won't start, check the fuel level and ensure fresh fuel is used. Verify that the fuel valve is in the "ON" position and the choke is set appropriately. Inspect the spark plug for fouling or damage and replace if necessary. Check that the engine switch is "ON" and the oil level is adequate.

What should I do if the generator is running roughly or stalls?

If the generator is running roughly or stalls, check the air filter for dirt or obstructions and clean or replace it as needed. Ensure the spark plug is clean and properly gapped. Inspect the fuel for contamination or water. Adjust the choke lever to the correct position for the current operating conditions.

How do I safely shut down the Subaru RG2800iS generator?

To safely shut down the generator, disconnect all electrical loads. Allow the generator to run for a few minutes without load to stabilize temperature. Turn the engine switch to the "OFF" position. Close the fuel valve. If storing the generator, let it cool down before covering or moving it.

How often should I replace the spark plug in the generator?

The spark plug in the Subaru RG2800iS generator should be inspected every 100 hours of operation and replaced if there are signs of wear or carbon build-up. It is advisable to replace the spark plug annually to ensure optimal performance.

Can I use the Subaru RG2800iS generator in wet weather?

The Subaru RG2800iS generator should not be used in wet weather conditions due to the risk of electrocution and damage to the generator. Always operate it in a dry, well-ventilated area and use a canopy or cover to protect it from moisture if necessary.

What is the proper way to store the generator when not in use?

For storage, first drain the fuel from the tank and carburetor to prevent gum deposits. Clean the generator and store it in a dry, dust-free area. Cover the generator to protect it from dust and moisture. Disconnect the battery if it will be stored for a long period.

How do I reset the circuit breaker on the Subaru RG2800iS generator?

To reset the circuit breaker on the Subaru RG2800iS generator, first turn off the generator and disconnect all electrical loads. Locate the circuit breaker on the control panel and switch it to the "OFF" position. Wait a few minutes, then switch it back to the "ON" position. Restart the generator and reconnect the loads one at a time.