To clean the filters, first remove them from the hood. Wash them in warm, soapy water or place them in the dishwasher. Ensure they are completely dry before reinstalling.
First, check if the bulb needs replacement. If the bulb is fine, inspect the wiring for any visible damage. Consult the manual to ensure proper installation of the bulb.
Ensure that the hood is securely mounted and that the filters are clean and correctly placed. Check for any loose parts that might vibrate during operation.
It is recommended to clean the filters once a month and inspect the hood for any signs of wear and tear every six months.
Press and hold the reset button on the control panel for 3 seconds until the indicator light turns off.
Check for blockages in the ductwork and ensure the filters are clean. Also, make sure the hood is set to the correct extraction speed.
Yes, you can install the hood yourself. You will need a screwdriver, measuring tape, level, and possibly a drill, depending on your kitchen setup. Follow the installation guide provided in the manual.
Excessive vibration can be caused by an imbalanced fan or loose mounting. Check the fan and ensure all screws and mounts are tightened.
Ensure the hood is turned off and cool. Remove the light cover, unscrew the bulb, and replace it with a new one of the same type and wattage.
The hood uses aluminum mesh filters that are reusable and should be cleaned regularly.