To ensure your Olympus PT-EP01 case is properly sealed, check the O-ring for any debris or damage, apply a thin layer of silicone grease to the O-ring, and close the case carefully, ensuring all latches are securely fastened.
If the buttons are sticking, rinse the case in fresh water to remove any salt or debris, and gently press each button while submerged. After rinsing, allow the case to dry completely. If the problem persists, inspect for any visible damage or debris.
To prevent fogging, ensure the case and camera are dry before sealing. Use anti-fog inserts or silica gel packs inside the case to absorb moisture. Additionally, avoid opening the case in humid conditions.
Regularly inspect the O-ring for damage or wear, clean it with fresh water and dry it thoroughly. Before each use, apply a thin layer of silicone grease to ensure a good seal and prevent cracking.
The Olympus PT-EP01 case is specifically designed for the Olympus E-PL1 camera model. Using it with other models may result in improper fit or damage. Always verify compatibility before use.
Rinse the case thoroughly in fresh water immediately after use in saltwater to remove any salt deposits. Use a soft cloth to gently clean the exterior and interior, and allow it to dry completely before storing.
If a leak is detected, immediately remove the camera and dry it thoroughly. Inspect the O-ring for damage or debris that may have caused the leak. Replace the O-ring if necessary and test the case without the camera to ensure it is watertight.
The Olympus PT-EP01 case is designed for use up to a depth of 40 meters (approximately 130 feet). Always adhere to this limit to prevent damage to the case and ensure safety.
The PT-EP01 case features accessory mounts and threads for attaching compatible strobes or lenses. Refer to the user manual for specific instructions on attaching each type of accessory securely.
Store the PT-EP01 case in a cool, dry place away from direct sunlight. Ensure the case is clean and dry before storage, and keep the O-ring removed and stored in a sealed bag to prevent deformation.