Jotul GI 350 DV Operating Instructions

To ignite the Jotul GI 350 DV Fireplace, ensure the gas valve is open, turn the control knob to the 'Pilot' position, press and hold the knob while pressing the igniter button. Once the pilot lights, continue to hold the knob for about 30 seconds before releasing.
If the pilot light won't stay lit, check for obstructions in the pilot assembly, ensure the thermocouple is properly positioned, and verify that the gas supply is adequate. If the problem persists, consult a professional technician.
Allow the glass panel to cool completely before cleaning. Use a non-abrasive fireplace glass cleaner and a soft cloth to gently wipe the glass. Avoid using ammonia-based cleaners or abrasive materials that can scratch the surface.
Regular maintenance includes cleaning the glass panel, inspecting and cleaning the burner and logs, checking the venting system for blockages, and inspecting the pilot assembly. It's advisable to have a professional service the fireplace annually.
Yes, the Jotul GI 350 DV Fireplace can be converted from natural gas to propane. This should be done by a qualified technician using a conversion kit provided by the manufacturer to ensure safety and proper operation.
Ensure the thermostat is set correctly, check for blockages in the vent system, verify the gas supply is adequate, and inspect the burner for debris. If issues persist, consult a professional technician.
To turn off the fireplace, rotate the control knob to the 'Off' position. If you will not be using the fireplace for an extended period, close the gas valve to ensure no gas is flowing to the unit.
Refer to the owner's manual for the recommended log arrangement. Proper log placement is crucial for optimal flame pattern and to prevent sooting or damage to the logs and burner.
If you smell gas, immediately turn off the fireplace and the gas supply. Open windows for ventilation and do not use electrical switches. Contact a professional technician to inspect the unit before using it again.
To adjust the flame height, use the control knob on the valve. Rotate the knob to a higher setting to increase the flame or to a lower setting to decrease it. Ensure the adjustment is within the manufacturer's recommended range.