Jotul C 350 Winterport Operating Instructions

Jotul C 350 Winterport Fireplace manual cover
Pages 24
Year 2018
Language(s)
English en

Jotul C 350 Winterport Fireplace Specification

The Jotul C 350 Winterport is a highly efficient wood-burning fireplace insert designed to enhance both the heating performance and aesthetic appeal of existing masonry fireplaces. Engineered with advanced combustion technology, it provides a clean and environmentally friendly burn, meeting stringent EPA standards.

This model features a compact design that fits seamlessly into smaller fireplaces, yet it offers substantial heat output. The unit has a heating capacity sufficient for spaces up to 1,300 square feet, making it ideal for medium-sized areas. The Jotul C 350 boasts a maximum heat output of 40,000 BTUs per hour, ensuring consistent warmth during cold weather conditions.

Constructed with durable cast iron, the fireplace insert retains heat efficiently, contributing to prolonged warmth even after the fire has subsided. Its large glass door offers an unobstructed view of the flames, enhancing the room's ambiance while the air-washed glass technology ensures a clear view with minimal maintenance. The insert includes an adjustable blower to optimize heat distribution throughout the living space.

The Jotul C 350 Winterport is designed for user convenience, featuring a single air control for easy operation and precise burn management. The unit accommodates logs up to 20 inches in length, reducing the need for frequent reloading. Installation is straightforward, with options for both top and rear venting to suit various chimney configurations.

Overall, the Jotul C 350 Winterport combines robust heating performance with timeless design, making it an excellent choice for homeowners seeking to upgrade their fireplace with an efficient and attractive insert.

Jotul C 350 Winterport Fireplace F.A.Q.

How do I properly light a fire in my Jotul C 350 Winterport fireplace insert?

To light a fire in your Jotul C 350 Winterport, start by placing crumpled newspaper and small kindling at the bottom center of the insert. Open the air vents fully to allow maximum airflow. Light the newspaper and allow the kindling to catch fire before adding larger logs. Once the fire is established, adjust the air vents to maintain the desired temperature.

What is the recommended cleaning schedule for the Jotul C 350 Winterport glass door?

The glass door of your Jotul C 350 Winterport should be cleaned weekly during regular use. Use a soft cloth and a non-abrasive glass cleaner specifically designed for fireplace glass to prevent scratching. Ensure the glass is cool before cleaning.

How can I improve the efficiency of my Jotul C 350 Winterport fireplace insert?

To improve efficiency, ensure that the fireplace insert is properly sealed and that the chimney is clean and unobstructed. Burn seasoned hardwood for optimal heat output and adjust the air controls to maintain a steady flame. Regular maintenance and inspection of the door gasket can also help improve efficiency.

What should I do if smoke is coming into the room from my Jotul C 350 Winterport?

If smoke enters the room, check to ensure the chimney is clear and not obstructed. Verify that the air vents are open and that there is enough draft in the chimney. The room should have adequate ventilation. If the problem persists, consult a professional chimney sweep or technician.

How do I replace the door gasket on my Jotul C 350 Winterport?

To replace the door gasket, first ensure the fireplace is completely cool. Remove the old gasket and clean the groove thoroughly. Apply a thin layer of high-temperature adhesive and press the new gasket into place. Allow the adhesive to cure as per the manufacturer's instructions before using the fireplace.

What type of wood should I use in my Jotul C 350 Winterport?

Use well-seasoned hardwoods such as oak, maple, or ash for the best performance in your Jotul C 350 Winterport. These woods burn hotter and longer, providing more efficient heating. Avoid softwoods or unseasoned wood, which can cause creosote buildup and inefficient burning.

How often should I have my Jotul C 350 Winterport chimney inspected?

It is recommended to have your chimney inspected and cleaned at least once a year, preferably before the start of the heating season. Regular inspections help prevent creosote buildup and ensure safe operation of your fireplace insert.

Can I operate my Jotul C 350 Winterport with the door open?

The Jotul C 350 Winterport is designed to operate with the door closed to ensure maximum efficiency and safety. Operating with the door open can lead to poor draft, smoke spillage, and increased risk of sparks escaping into the room.

What should I do if the blower on my Jotul C 350 Winterport stops working?

If the blower stops working, first check the power supply and ensure the unit is plugged in. Inspect the blower motor for any obstructions or debris. If necessary, consult the user manual for troubleshooting steps or contact a qualified technician for service.

How can I prevent creosote buildup in my Jotul C 350 Winterport?

To prevent creosote buildup, burn only seasoned hardwood and maintain proper airflow by keeping air vents appropriately adjusted. Regularly inspect and clean the chimney, and ensure the fireplace insert is burning at an optimal temperature.