Clarke 7610020 CFT24 Fuel Transfer Instructions
![Clarke 7610020 CFT24 Fuel Transfer Pump manual cover](/images/qtegXJEIIbKNmDQOxPALCZUn/thumbs/thumb175x175.webp)
To set up the Clarke 7610020 CFT24 Fuel Transfer Pump, ensure that the pump is securely mounted on a stable surface. Connect the inlet and outlet hoses to the respective ports, making sure all connections are tight to prevent leaks. Check that the power source meets the pump's specifications and connect it using the appropriate cables. Prime the pump by filling the inlet hose with fuel before starting it.
If the pump doesn't start, first check the power supply to ensure it's connected properly and functioning. Inspect the fuse and replace it if necessary. Verify that the on/off switch is in the correct position. Check for any obstructions or debris in the pump that might impede operation. If the problem persists, consult the user manual or seek professional assistance.
Regular maintenance is crucial for optimal performance. It is recommended to perform a basic inspection monthly, checking for leaks and ensuring all connections are secure. Every six months, conduct a more thorough examination, cleaning any components as needed and replacing worn parts. Always refer to the user manual for specific maintenance guidelines.
The Clarke 7610020 CFT24 Fuel Transfer Pump is designed to handle diesel, kerosene, and light oils. It is not suitable for gasoline or other highly flammable or corrosive liquids. Always consult the pump's specifications to ensure compatibility with the fuel type you intend to use.
To troubleshoot a leak, first turn off the pump and disconnect it from the power source. Inspect all hose connections and fittings for signs of wear or damage. Tighten any loose connections and replace damaged hoses or seals. Restart the pump and observe if the leak persists. If it does, further inspection by a professional may be required.
If the pump runs but doesn't transfer fuel, check for blockages in the inlet or outlet hoses. Ensure that the suction line is submerged in fuel and that the pump is properly primed. Verify that all valves are open and functioning. If these steps don't resolve the issue, there may be a problem with the pump's internal components, requiring professional service.
To improve efficiency, ensure that the pump is properly maintained and all components are clean and in good condition. Use the shortest possible length of hose to minimize resistance. Avoid sharp bends or kinks in the hoses. Regularly check and replace any worn or damaged parts to maintain optimal performance.
The Clarke 7610020 CFT24 is capable of operating in cold weather, but performance may be affected. Ensure that the fuel being transferred is suitable for low temperatures and that hoses and seals are not compromised by the cold. It may be necessary to warm the pump or fuel slightly to ensure smooth operation.
Always operate the pump in a well-ventilated area to prevent the buildup of fumes. Wear appropriate personal protective equipment, such as gloves and goggles. Keep flammable materials away from the pump and fuel source. Follow all manufacturer guidelines and local safety regulations to ensure safe operation.
When storing the pump, disconnect it from the power source and drain any remaining fuel from the system. Clean the pump and hoses thoroughly to remove any residue. Store in a dry, cool place away from direct sunlight and extreme temperatures. Cover the pump to protect it from dust and debris.