Perkins 2806F-E18TA Operation Manual

Perkins 2806F-E18TA Engine manual cover
Pages 120
Year 2019
Language(s)
English en

Perkins 2806F-E18TA Engine Specification

The Perkins 2806F-E18TA engine is a robust, 18.1-liter power unit designed to meet the rigorous demands of industrial applications. This 6-cylinder, inline diesel engine is turbocharged and air-to-air charge cooled, ensuring high performance and efficiency. It delivers a power output of up to 597 kW (800 hp) at 1800 rpm, making it ideal for heavy-duty machinery that requires consistent and reliable power. The engine is equipped with an advanced electronic control system, enhancing fuel efficiency and reducing emissions in compliance with stringent regulatory standards, such as EU Stage V and EPA Tier 4 Final.

The high-pressure common rail fuel system in the 2806F-E18TA ensures precise fuel delivery, optimizing combustion and minimizing fuel consumption. It operates with a bore and stroke of 145 mm x 183 mm, and its compact design facilitates easy integration into a wide range of equipment. The engine features a dual rear gear train and overhead camshaft that contribute to its durability and low maintenance requirements.

Cooling is managed by a liquid system, which maintains optimal operating temperatures, while a high-capacity oil pump ensures effective lubrication, enhancing engine longevity. The engine's construction includes a cast iron block and head, providing strength and resistance to thermal stress. Noise and vibration are minimized through its balance shaft and isolated components, ensuring smoother operation.

Overall, the Perkins 2806F-E18TA engine stands out for its high power density, reliability, and operational efficiency, making it a preferred choice for industrial applications requiring robust performance and compliance with modern emission standards.

Perkins 2806F-E18TA Engine F.A.Q.

What is the recommended oil type for the Perkins 2806F-E18TA engine?

The recommended oil type for the Perkins 2806F-E18TA engine is a high-quality SAE 15W-40 API CI-4/CH-4 oil. Ensure that the oil meets the necessary specifications for optimal performance and longevity.

How often should I perform routine maintenance on the Perkins 2806F-E18TA engine?

Routine maintenance for the Perkins 2806F-E18TA engine should be performed every 500 hours or as specified in the engine's operation and maintenance manual. Regular checks include oil changes, filter replacements, and inspections of belts and hoses.

How do I troubleshoot an overheating issue in the Perkins 2806F-E18TA engine?

To troubleshoot overheating in the Perkins 2806F-E18TA engine, check for coolant levels, inspect the radiator for blockages, ensure the fan is functioning correctly, and verify the thermostat operation. Address any leaks or damaged components immediately.

What are the steps to replace the air filter on the Perkins 2806F-E18TA engine?

To replace the air filter on the Perkins 2806F-E18TA engine, first, stop the engine and allow it to cool. Open the air filter housing, remove the old filter, and clean the housing. Install the new filter, ensuring it is properly seated, then close the housing securely.

Can the Perkins 2806F-E18TA engine run on biodiesel?

Yes, the Perkins 2806F-E18TA engine can run on biodiesel blends up to B20 (20% biodiesel, 80% petroleum diesel). Ensure the biodiesel meets the ASTM D6751 or EN 14214 standard to maintain engine performance and warranty.

What is the procedure to bleed air from the fuel system on the Perkins 2806F-E18TA engine?

To bleed air from the fuel system on the Perkins 2806F-E18TA engine, locate the bleed screws on the fuel filter and fuel injection pump. Loosen the screws and manually pump the priming lever until fuel free of air bubbles flows, then tighten the screws securely.

How do I reset the diagnostic trouble codes on the Perkins 2806F-E18TA engine?

To reset diagnostic trouble codes on the Perkins 2806F-E18TA engine, use a compatible diagnostic tool to access the engine's electronic control module (ECM). Follow the tool's instructions to clear the codes. Ensure to address any underlying issues before resetting.

What could cause a loss of power in the Perkins 2806F-E18TA engine?

Loss of power in the Perkins 2806F-E18TA engine can be caused by clogged air or fuel filters, low fuel pressure, turbocharger issues, or exhaust restrictions. Inspect these components and replace or service them as necessary to restore power.

How should I store the Perkins 2806F-E18TA engine when not in use for extended periods?

For extended storage of the Perkins 2806F-E18TA engine, drain the fuel system, change the oil, remove the battery, and store it in a cool, dry place. Cover the engine to protect it from dust and moisture, and rotate the crankshaft periodically to prevent seizing.

What are the causes of excessive smoke emission from the Perkins 2806F-E18TA engine?

Excessive smoke emission from the Perkins 2806F-E18TA engine can result from fuel injection issues, turbocharger failure, air intake blockages, or worn engine components. Conduct a thorough inspection and repair or replace faulty parts.