Perkins 2806EA-E18TA Operation Manual
![Perkins 2806EA-E18TA Engine manual cover](/images/ioVjvIcYfkgnjAaackIzrTHG/thumbs/thumb175x175.webp)
The recommended oil type for the Perkins 2806EA-E18TA engine is a high-quality diesel engine oil that meets the API CI-4 or ACEA E5 specification.
The oil filter should be changed every 250 hours of operation or as specified in the maintenance schedule provided in the engine's manual.
If the engine exhibits high coolant temperature, check for coolant level, radiator obstructions, and ensure the fan is operating correctly. If the issue persists, inspect the thermostat and water pump.
To troubleshoot an engine that won't start, check the battery charge, fuel supply, and ensure the fuel filter is not clogged. Verify the integrity of electrical connections and test the starter motor.
The air filter should be inspected every 250 hours and replaced every 500 hours of operation, or more frequently in dusty conditions.
To optimize fuel efficiency, regularly maintain the engine according to the manufacturer's schedule, use high-quality fuel, and ensure proper engine load management and operation at optimum RPM.
Black smoke emissions can be caused by air filter blockage, incorrect fuel injection timing, excessive engine load, or a malfunctioning turbocharger.
To reset the service light, follow the procedure outlined in the engine's operator manual, which typically involves using the engine's control panel or diagnostic tool.
Winterizing involves draining the cooling system, adding antifreeze, checking battery condition, and ensuring all lubricants are appropriate for low temperatures.
For long-term storage, clean the engine, change the oil, drain the fuel system, disconnect the battery, and cover the engine to protect it from dust and moisture.