Bostitch CAP1615-OF Instruction Manual
![Bostitch CAP1615-OF Compressor manual cover](/images/qlHjfaGMLStdDOOJxKdqAFjK/thumbs/thumb175x175.webp)
To set up the Bostitch CAP1615-OF Compressor, ensure the unit is on a flat surface, connect the air hose to the compressor outlet, attach the desired tool, and plug the compressor into a power source. Adjust the pressure regulator to the appropriate setting for your tool.
First, check that the power cord is connected to a working outlet. Ensure the power switch is in the 'ON' position. Inspect the circuit breaker and reset if necessary. If the compressor still does not start, check for a blown fuse or contact customer service.
Regular maintenance includes checking and cleaning the air filter, draining the tank to remove moisture, inspecting hoses for wear or leaks, and ensuring all connections are tight. Regularly check the oil level if applicable.
To drain the air tank, turn off the compressor and unplug it from the power source. Open the drain valve at the bottom of the tank and allow the moisture to escape until the tank is completely empty. Close the valve securely after draining.
Check for leaks in the hose or connections, ensure the drain valve is closed, and inspect the pressure regulator for proper settings. If the problem persists, the pressure switch or valve may need servicing.
Using an extension cord is not recommended as it can lead to voltage drop and power loss. If necessary, use a heavy-duty extension cord with adequate current rating and keep it as short as possible.
The compressor is best operated in temperatures between 40°F and 100°F (4°C and 38°C). Operating outside this range may affect performance and longevity.
Position the compressor on a sound-dampening mat or pad, ensure all nuts and bolts are tight, and operate the compressor in a well-insulated space. Regular maintenance can also prevent noise due to worn parts.
Service intervals vary based on usage, but generally, it is recommended to perform a basic maintenance check every 3 months and a comprehensive service annually.
Always wear safety goggles and hearing protection, never point the air nozzle at yourself or others, avoid using in wet conditions, and follow all manufacturer instructions.