Yamaha EF7200DE, EF7200D v3 Owner's Manual
Generator
LIT-19626-02-83 7P6-F8199-15
PRINTED IN CHINA 2021.061 !
(E)
EF7200DE EF7200D
OWNERS MANUAL
Read this manual carefully before operating your Yamaha generator.
7P6-F8199-15_hyoshi.indd 1-2 2021/06/23 11:43:52
Read this manual carefully before operating your Yamaha generator. This manual should stay with this generator if it is sold.
7P6-F8199-15_hyoshi.indd 3-4 2021/06/23 11:43:52
INTRODUCTION Congratulations on your purchase of your new Yamaha Generator. This manual will provide you with a good basic understanding of the operation and maintenance of this generator. If you have any questions regarding the operation or maintenance of your generator, please consult a Yamaha dealer.
EF7200DE/EF7200D OWNERS MANUAL
2021 by Yamaha Motor Corporation, U.S.A. 1st Edition, June 2021
All rights reserved. Any reprinting or unauthorized use without the written permission of Yamaha Motor Corporation, U.S.A.
is expressly prohibited. Printed in China
P/N LIT-19626-02-83
7P6-F8199-15.indd 1 2021/06/23 11:43:09
Particularly important information is distin- guished in this manual by the following notations.
This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messag- es that follow this symbol to avoid pos- sible injury or death.
WARNING
A WARNING indicates a hazardous sit- uation which, if not avoided, could result in death or serious injury.
NOTICE
A NOTICE indicates special precau- tions that must be taken to avoid dam- age to the generator or other property.
TIP A TIP provides key information to make procedures easier or clearer.
WARNING
PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE GENERATOR.
TIP 9 Yamaha continually seeks advance-
ments in product design and quality. Therefore, while this manual contains the most current product information available at the time of printing, there may be minor discrepancies between your generator and this manual. If there is any question concerning this manual, please consult a Yamaha dealer.
9 This manual should be considered a permanent part of this generator and should remain with this generator when resold.
* Product and specifications are subject to change without notice.
7P6-F8199-15.indd 2 2021/06/23 11:43:09
SAFETY INFORMATION ...................... 1 Exhaust Fumes are Poisonous .......... 1 Carbon Monoxide Poisoning .............. 2 Fuel is Highly Flammable and Poisonous........................................... 3 Engine and Muffler May be Hot .......... 3 Electric Shock Prevention .................. 4 Connection Notes ............................... 5 Connection ......................................... 5 Extension Cord Notes ........................ 5
LOCATION OF IMPORTANT LABELS ................................................ 6 DESCRIPTION ...................................... 7
Control Panel (For EF7200DE) .......... 8 Control Panel (For EF7200D) ............. 8
CONTROL FUNCTION ......................... 9 Engine Switch .................................... 9 Oil Warning Light (Red) ...................... 9 CO SENSOR .................................... 10 AC Switch (N.F.B.) ............................ 14 Fuel Tank Cap .................................. 14 Fuel Cock Lever ............................... 14 Ground (Earth) Terminal ................... 15 Economy Control Switch .................. 15 Choke Lever ..................................... 15 Recoil Starter ................................... 16 Starter Switch (For EF7200DE) ....... 16 Voltage Adjuster ............................... 17 G.F.C.I. Receptacle .......................... 17
PREPARATION ................................... 18 Two Wheel Kit Installation ................ 18 Fuel .................................................. 23 Engine Oil ......................................... 25 Battery (For EF7200DE) .................. 26 Ground (Earth) Terminal ................... 27
PRE-OPERATION CHECK ................. 28 Pre-Operation Check ....................... 28
OPERATION ....................................... 29 Starting The Engine ......................... 29 Stopping The Engine ........................ 32 Connection ....................................... 34 Application Range ............................ 37 High Altitude Operation ................... 38
PERIODIC MAINTENANCE ................ 39 Maintenance Chart ........................... 39 Carburetor Adjustment ..................... 41 Spark Plug Inspection ...................... 41 Engine Oil Replacement .................. 42 Muffler Screen and Spark Arrester... 44 Air Filter ............................................ 46 Fuel Cock ......................................... 47 Fuel Tank Filter ................................. 48 Battery (For EF7200DE) .................. 49 Recommended Battery (For EF7200DE) ............................... 49 Fuse Replacement (For EF7200DE) ............................... 50 G.F.C.I. Receptacle Test ................... 51
STORAGE ........................................... 52 Drain The Fuel .................................. 52 Engine .............................................. 53 Battery (For EF7200DE) .................. 54
TROUBLESHOOTING ........................ 55 SPECIFICATIONS ............................... 60
Dimensions ...................................... 60 Engine .............................................. 60 Generator ......................................... 60
CONSUMER INFORMATION.............. 61 Identification Number Records ......... 61 Generator Identification .................... 61
EXHAUST EMISSION CONTROL SYSTEM AND COMPONENTS .......... 62 WIRING DIAGRAM ............................. 63
EF7200DE ........................................ 63 EF7200D .......................................... 64
YAMAHA EXTENDED SERVICE (Y.E.S.) ................................................ 65
CONTENTS
7P6-F8199-15.indd 3 2021/06/23 11:43:09
1
SAFETY INFORMATION 9 This generator is not designed for on-board use.
Do not use it while installed on the vehicle.
9 Do not modify the generator or use it with its parts removed.
9 Do not allow children to operate the generator.
9 Do not place any obstacles on the generator.
Exhaust Fumes are Poisonous 9 Using a generator indoors CAN KILL YOU IN
MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
9 NEVER use inside a home or garage, EVEN IF doors and windows are open.
9 Only use OUTSIDE and far away from windows, doors, and vents with engine exhaust directed away from any structures.
7P6-F8199-15.indd 1 2021/06/23 11:43:09
2
Carbon Monoxide Poisoning 9 CO gas is toxic and can cause serious injury or
death.
9 Get fresh air and seek medical care immediately, if you are suspected to be inhaled carbon monoxide.
9 Early symptoms of carbon monoxide exposure include headache, fatigue, shortness of breath, nausea, and dizziness and so on. Continued expo- sure to carbon monoxide can cause loss of mus- cular coordination, loss of consciousness, and then result in death.
9 This generator is equipped with the CO SENSOR system that automatically stops the engine before the surrounding carbon monoxide concentration increases to a dangerous concentration.
9 Do not remove or modify the CO SENSOR sys- tem.
9 Make sure that the CO SENSOR system works correctly.
9 The CO SENSOR cannot prevent all danger asso- ciated with or caused by carbon monoxide. Pay careful attention to the location of the generator.
9 If the CO SENSOR stopped the generator, relo- cate the generator and address symptoms of car- bon monoxide poisoning prior to restart the gener- ator.
9 Install battery-operated or plug-in carbon monox- ide alarms to alert you to potentially dangerous levels of carbon monoxide in accordance with the alarms instructions.
7P6-F8199-15.indd 2 2021/06/23 11:43:09
3
Fuel is Highly Flammable and Poisonous 9 Always turn off the engine when refuelling.
9 Never refuel while smoking or in the vicinity of an open flame.
9 Take care not to spill any fuel on the engine or muffler when refuelling.
9 Do not leave the generator inside the vehicle or in the trunk.
9 If you swallow any fuel, inhale fuel vapor, or allow any to get in your eye(s), see your doctor immedi- ately. If any fuel spills on your skin or clothing, immediately wash with soap and water and change your clothes.
9 When operating or transporting the generator, be sure it is kept upright. If it tilts, fuel may leak from the carburetor or fuel tank.
Engine and Muffler May be Hot 9 Place the generator in a place where pedestrians
or children are not likely to touch the generator.
9 Avoid placing any flammable materials near the exhaust outlet during operation.
9 In order to prevent overheating, ensure adequate airflow by keeping the generator at least 1 m (3 ft) from objects or other equipment.
9 Do not operate the engine with a dust cover or other objects covering it.
9 When covering the generator, be sure to do so only after the engine and muffler have completely cooled down.
7P6-F8199-15.indd 3 2021/06/23 11:43:09
4
Electric Shock Prevention 9 Never operate the engine in rain or snow.
9 Never touch the generator with wet hands or elec- trical shock will occur.
9 When the connected electric device is grounded (earthed), always ground (earth) the generator.
9 Connect the ground (earth) terminal to a ground source. In order to prevent electrical shock, the generator must be grounded when using a grounded electrical device.
1 Ground (earth) terminal
1
7P6-F8199-15.indd 4 2021/06/23 11:43:09
5
741-040a
1
2
1
2
Connection Notes 9 Avoid connecting the generator to commercial
power outlet. 9 Avoid connecting the generator in parallel with any
other generator.
1 Correct 2 Incorrect
Connection
WARNING
Before the generator can be connected to a build- ings electrical system, a licensed electrician must install an isolation (transfer) switch in the build- ings main fuse box. The switch is the connection point for generator power and allows selection of generator or main line power to the building. This will prevent the generator from charging the main power line (backfeeding) when the main power supply has failed or has been turned off for line repair. Backfeeding can electrocute or injure line maintenance personnel. Also, generator and build- ing electrical system damage can occur when nor- mal operating power returns if unit is used without an isolation switch.
Extension Cord Notes Extension cords should be protected by a tough flexi- ble rubber sheath (IEC 245) or the equivalent to with- stand mechanical stresses.
7P6-F8199-15.indd 5 2021/06/23 11:43:09
6
LOCATION OF IMPORTANT LABELS Please read the following labels carefully before oper- ating this generator. TIP Maintain or replace safety and instruction labels, as necessary.
2
4
O I L
5
DISPLACEMENT :
3
6
DANGER Using a generator indoors CAN KILL YOU IN MINUTES.
Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell.
NEVER use inside a home or garage, EVEN IF doors and windows are open.
Only use OUTSIDE and far away from windows, doors, and vents. 7C2-F4877-00
1
7
8
1
2
34
5
6 7 8
7P6-F8199-15.indd 6 2021/06/23 11:43:10
7
DESCRIPTION 1 Carrying handles (shaded) 2 Fuel tank cap 3 Fuel level gauge 4 Fuel tank 5 Voltage adjuster 6 Ground (earth) terminal 7 Battery (For EF7200DE) 8 Oil filler cap 9 Oil drain bolt 0 Spark plug q Fuel cock w Recoil starter handle e Air filter case cover r Choke lever t Muffler
EF7200DE
EF7200D
0 q
w
r e t
0 q
w
r e t
2
8
5
6
1 13 4
9 7
2
5
6
1 13 4
8 9
7P6-F8199-15.indd 7 2021/06/23 11:43:10
8
Control Panel (For EF7200DE) 1 Starter switch 2 Economy control
switch 3 Engine switch 4 Voltage/hour meter 5 G.F.C.I. receptacle 6 AC receptacle 7 AC switch (N.F.B.) 8 ERR (Error) indicator
light (Orange) 9 Oil warning light (Red) 0 WARNING indicator
light (Red)
EF7200DE
Control Panel (For EF7200D) 1 Economy control
switch 2 Engine switch 3 Voltage/hour meter 4 G.F.C.I. receptacle 5 AC receptacle 6 AC switch (N.F.B.) 7 ERR (Error) indicator
light (Orange) 8 Oil warning light (Red) 9 WARNING indicator
light (Red)
EF7200D
7
3 421 5 6 7
90 8
6
2 31 4 5 6
89 7
7P6-F8199-15.indd 8 2021/06/23 11:43:11
9
1
2
CONTROL FUNCTION Engine Switch The engine switch controls the ignition system.
1 7 (ON) Ignition circuit is switched on. The engine can be started.
2 5 (STOP) Ignition circuit is switched off. The engine will not run.
700-027c
Oil Warning Light (Red) When the oil level falls below the lower level, the oil warning light comes on and then the engine stops automatically. Unless you refill with oil, the engine will not start again.
TIP If the engine stalls or does not start, turn the engine switch to 7 (ON) and then push the starter switch (for EF7200DE) or pull the recoil starter. If the oil warn- ing light flickers for a few seconds, the engine oil is insufficient. Add oil and restart.
7P6-F8199-15.indd 9 2021/06/23 11:43:11
10
1 2
CO SENSOR The CO SENSOR is a system that automatically stops the engine before the surrounding CO concentration exceeds a certain level.
WARNING
9 Do not remove or modify the CO SENSOR sys- tem.
9 The CO SENSOR cannot prevent all danger associated with or caused by carbon monox- ide. Pay careful attention to the location of the generator.
9 Do not spray any organic solvent on the CO SENSOR.
There are two indicator lights in relation to the CO SENSOR.
1 WARNING indicator light (Red) 2 ERR (Error) indicator light (Orange)
WARNING indicator light (Red) If the CO SENSOR detects a high carbon monoxide concentration, the engine will stop and the WARNING indicator light will flash for approximately 5 minutes.
WARNING
Continuous use of the generator in areas with high concentrations of carbon monoxide can cause serious health hazards due to carbon monoxide poisoning. If you are in the same area as the gen- erator, evacuate the area immediately. Get fresh air and seek medical attention immediately, if you feel sick or suspect you have inhaled carbon monox- ide. Ventilate the area or space where the genera- tor is located.
7P6-F8199-15.indd 10 2021/06/23 11:43:11
11
If the engine is stopped by the CO SENSOR system, change the operating location of the generator to well- ventilated area.
TIP 9 Place the generator so that the muffler is pointed
in the same direction as the wind is blowing, and the exhaust gas is directed away from buildings, other structures, or vehicles.
9 Avoid placing the generator near devices that emit carbon monoxide, such as other generators.
WARNING
9 Do not operate the generator in an enclosed or partly enclosed area such as a garage.
9 Do not enclose or cover the generator with boards or a tent, even if it is outside and away from of a building.
While this indicator light is flashing and the CO SENSOR is activated, the engine cannot be restarted for approximately 5 minutes. Restarting the generator is possible only after the WARNING indicator light is turned off.
7P6-F8199-15.indd 11 2021/06/23 11:43:11
12
ERR (Error) indicator light (Orange) If the CO SENSOR detects a system malfunction or service life over, the engine will stop automatically and the ERR (Error) indicator will come on approximately 5 minutes.
TIP 9 The CO SENSOR has a limited service life and
must be replaced when it no longer functions. The battery is non-replaceable battery.
9 The generator stopping period and storage period are also in the useful service life of the CO SENSOR.
9 The lithium battery adopted on this sensor con- tains perchlorate, a toxic substance controlled in perchlorate Best Management Practices (BMP) regulations passed by the California legislature. When you discard the lithium battery in California, USA, please follow the related regulations in advance.
Perchlorate material-special handling may apply, see www.dtsc.ca.gov/hazardouswaste/perchlorate
9 Consult a Yamaha dealer for the CO SENSOR replacement.
7P6-F8199-15.indd 12 2021/06/23 11:43:11
13
On starting the engine Each indicator light flashes 5 times upon starting. When starting the engine, make sure that each indica- tor light flashes 5 times.
WARNING
9 If the indicator lights do not flash 5 times upon starting, discontinue generator use immediate- ly and consult a Yamaha dealer. The CO SENSOR system may be malfunctioning.
9 If the CO SENSOR WARNING indicator light (red) is flashing, immediately clear the area of all people and animals while moving the gen- erator to an open, outdoor area. Once the gen- erator is relocated to a well-ventilated area, it can be restarted after 5 minutes. Be sure to point the exhaust away from people and build- ings. Thoroughly ventilate the location where the generator had stopped.
9 If the CO SENSOR system is malfunctioning, it cannot warn you of potential high concentra- tions of carbon monoxide. Move the generator to a well-ventilated location and consult a Yamaha dealer.
9 While the CO SENSOR is activated, the engine cannot be restarted for approximately 5 min- utes. Relocate the generator and address symptoms of carbon monoxide poisoning prior to restart the generator.
NOTICE
If you stop the engine in the following situations, the CO SENSOR system may not be able to restart the engine immediately. Wait approximately 15 sec- onds before restarting the engine. 9 By the engine switch. 9 By the oil level warning device. 9 By running out of gasoline.
TIP If the indicator lights come on or flash abnormally, check TROUBLESHOOTING (See page 56).
7P6-F8199-15.indd 13 2021/06/23 11:43:11
14
AC Switch (N.F.B.) The AC switch (Non-Fuse Breaker) turns off automati- cally when the load exceeds the generator rated out- put.
1 I (ON) 2 3 (OFF)
1
2
1
2
2
1A
11B
Supplies AC 120 V
Supplies AC 120 V and 240 V
NOTICE
Reduce the load to the specified generator rated output if the AC switch (N.F.B.) turns off. If it turns off again, consult a Yamaha dealer.
Fuel Tank Cap Remove the fuel tank cap by turning it counterclock- wise.
7DF-1061
22
Fuel Cock Lever The fuel cock supplies fuel from the fuel tank to the carburetor. The fuel cock has two positions.
1 ON With the lever in this position, fuel flows to the carbure- tor. Normal using is done with the lever in this position.
2 OFF With the lever in this position, fuel will not flow. Always turn the lever to this position when the engine is not running.
7P6-F8199-15.indd 14 2021/06/23 11:43:12
15
1
Ground (Earth) Terminal Ground (earth) terminal connects the earth line for prevention of electric shock. When the electric device is earthed, always the gener- ator must be earthed.
1 Ground (earth) terminal
1 Choke Lever Starting a cold engine requires a richer air-fuel mix- ture, which is supplied by the choke lever.
1 Choke lever
1
2
240V
120V
120V
GR
W X
G Y
Economy Control Switch
1 I (ON) When the economy control switch is turned to I (ON), the economy control unit controls the engine speed according to the connected load. The results are better fuel consumption and less noise.
2 3 (OFF) When the economy control switch is turned to 3 (OFF), the engine runs at the rated r/min (3600 r/min) regardless of whether there is a load connected or not.
TIP 9 The economy control switch must be turned to 3
(OFF) when using electric devices that require a large starting current, such as a compressor or a submersible pump.
9 The economy control switch must be turned to 3 (OFF) to increase engine speed to rated r/min when:
- using a load of 0.8 A or less. - supplying AC 120 V only from W with X.
7P6-F8199-15.indd 15 2021/06/23 11:43:12
16
Starter Switch (For EF7200DE) The starter switch controls the following item.
Push: Starting circuit is switched on.
Release: Starting circuit is switched off.
NOTICE
Take your hand off the switch immediately after the engine starts.
Recoil Starter The recoil starter is used to start the engine. Grasp the recoil starter handle and pull slowly until resistance is felt. Give the starter handle and rope a short, brisk pull to start the engine.
1 Recoil starter handle
NOTICE
9 Grasp the carrying handle firmly to prevent the generator from falling over when pulling the recoil starter.
9 Pull the recoil starter handle straight out. Pulling at an angle could damage the recoil starter rope or other generator parts.
9 Do not allow the starter handle and rope to snap back after starting; return it gently to its original place. Letting go of the handle while the starter rope is extended will allow the recoil starter to rewind rapidly, which can cause damage to the generator.
9 Do not touch the recoil starter handle while the generator is operating.
1
7P6-F8199-15.indd 16 2021/06/23 11:43:12
17
000-000
Voltage Adjuster The voltage adjuster is equipped for adjusting output voltage to rated voltage.
TIP Turn the voltage adjuster clockwise or counterclock- wise to increase or decrease output voltage.
3
763-060
G.F.C.I. Receptacle
WARNING
TO REDUCE THE CHANCE OF ELECTRICAL SHOCK: 9 Do not attempt to operate electric devices if
the ground fault circuit interrupter reset button pops out repeatedly during use.
9 Test the ground fault circuit interrupter during the pre-operation checks according to the maintenance instructions on page 51.
9 Remember that only receptacle labeled GFCI have ground fault circuit interrupter protection.
The G.F.C.I. (Ground Fault Circuit Interrupter) shuts off power to the protected receptacles if a ground fault (electrical leak) is detected. If the reset button pops out, the electric devices con- nected into the receptacle may be faulty. If this hap- pens, check the electric devices carefully. If the electric devices appears to be in good condition, press the reset button firmly until a click is heard. This will restore power. If the reset button pops out again, dis- connect all the electric devices immediately. Have the electric devices inspected and repaired by a qualified repairperson before attempting to use them again.
1 G.F.C.I. (Ground Fault Circuit Interrupter) 2 Reset button 3 Pop out
000-000
1
2
7P6-F8199-15.indd 17 2021/06/23 11:43:12
18
PREPARATION Two Wheel Kit Installation 1. Fasten the engine hanger to the carrier frame with
the bolts. TIP Match the punch marks as shown in the illustration.
1 Bolt (8 16 mm Flange bolt) 2 Engine hanger 3 Carrier frame
Tightening torque: 16 Nm (1.6 kgfm, 12 lbft)
2. Install the damper and plate into the stopper, and tightly fasten it to carrier frame with the bolt.
4 Damper 5 Plate 6 Stopper 7 Bolt (6 16 mm Flange bolt)
Tightening torque: 7 Nm (0.7 kgfm, 5.2 lbft)
000-000
1
2
3
1
000-000
000-000
4
5
6
000-000
7
7P6-F8199-15.indd 18 2021/06/23 11:43:13
19
4. Place the carrier frame on the generator body so that the lock lever is positioned on the left side of the control panel. Fasten the plate to the carrier frame with the bolts.
TIP Place the carrier frame 10 cm (3.94 in) from the end of generator body.
a 10 cm (3.94 in)
Tightening torque: 16 Nm (1.6 kgfm, 12 lbft)
r Bolt (8 45 mm Flange bolt) t Plate
3. Insert the bolt into the carrier frame, and then put the washer, collar, and lock lever in this order, and tighten the nut.
TIP 9 Make sure that the collar is placed into the washer. 9 Lock lever pin should be above stopper.
8 Nut (8 mm Flange nut [Self-locking nut]) 9 Lock lever 0 Collar q Washer (Plastic) w Bolt (8 60 mm Flange bolt) e Stopper
Tightening torque: 16 Nm (1.6 kgfm, 12 lbft)
a
000-000
r
t
t
000-000
r
t
000-000
8 9
0 q
w
000-000
9 e
7P6-F8199-15.indd 19 2021/06/23 11:43:13
20
8. Place the handle on the carrier frame, and then fasten the handle with the lock lever.
p Handle a Lock lever
9. Tighten the bolts.
s Bolt (8 16 mm Flange bolt)
Tightening torque: 16 Nm (1.6 kgfm, 12 lbft)
000-000
p
a
000-000
s
s
000-000
5. Install the sleeve on the generator frame. TIP Refer to the illustration to be sure that the sleeve is installed properly.
y Sleeve u Generator frame
6. Install the bracket handle to the sleeve.
i Bracket handle
7. Install the locating damper on the sleeve.
o Locating damper
000-000
y u
000-000
y
i
000-000
y
o
7P6-F8199-15.indd 20 2021/06/23 11:43:14
21
10. Lift the generator 20 cm (7.87 in) off the ground using a winch or other suitable lifting device.
11. Fasten the main stand to the left side of the gener- ator frame as viewed when looking at the control panel with the bolts and nuts.
d Bolt (8 16 mm Flange bolt) f Main stand g Nut (8 mm Flange nut)
Tightening torque: 16 Nm (1.6 kgfm, 12 lbft)
12. Install the wheels into wheel axle frame. TIP Make sure the installation direction of the wheels are correct.
d f
gg
gg
f
d
7P6-F8199-15.indd 21 2021/06/23 11:43:14
22
15. Fasten the wheel axle frame to the generator frame with the bolts and nuts. Make sure that the wheel axle frame is on the right side of the control panel.
l Bolt (8 16 mm Flange bolt) ; Wheel axle frame z Nut (8 mm Flange nut)
Tightening torque: 16 Nm (1.6 kgfm, 12 lbft)
TIP Refer to the illustration and confirm the position of the wheel kit.
j
h
k
k
; z
l
z
l
h
j
k
13. Install the washers into wheel axle. 14. Insert cotter pins into wheel axle frame, and then
bend as shown in the illustration.
h Wheel j Washer k Cotter pin
7P6-F8199-15.indd 22 2021/06/23 11:43:15
23
Fuel
WARNING
9 Fuel is highly flammable and poisonous. Check SAFETY INFORMATION (See page 3) carefully before filling.
9 Do not overfill the fuel tank, otherwise it may overflow when the fuel warms up and expands.
9 Wipe up any spilled fuel immediately. 9 Never refuel while smoking or in the vicinity of
an open flame. 9 Touch a metal surface on the generator before
refueling to discharge any static electricity. Sparks could cause fire or explosion.
9 After adding fuel, make sure the fuel tank cap is tightened securely.
1. Stop the engine. 2. Place the generator on a level surface. 3. Remove the fuel tank cap. 4. Check the fuel level. 5. If low, fill the tank with fuel.
NOTICE
9 Immediately wipe off spilled fuel with a clean, dry, soft cloth, since fuel may deteriorate paint- ed surfaces or plastic parts.
9 Use only unleaded gasoline. The use of leaded gasoline will cause severe damage to internal engine parts.
9 If foreign materials enter the fuel tank, they may clog the fuel line. Be sure the fuel tank fil- ter is installed before adding fuel.
7P6-F8199-15.indd 23 2021/06/23 11:43:15
24
.
Recommended fuel: Unleaded gasoline Fuel tank capacity: Total: 26 L (6.87 US gal, 5.72 Imp gal)
4 F Full 5 E Empty
Your Yamaha engine has been designed to use regu- lar unleaded gasoline with a pump octane number ((R + M)/2) of 86 or higher, or research octane number of 91 or higher.
45
7DK-093
1 2 Make sure there is sufficient fuel in the tank. When refueling, do not fill the tank up above the top edge of the fuel tank filter.
1 Fuel level 2 Fuel tank filter 3 Fuel level gauge
3
7P6-F8199-15.indd 24 2021/06/23 11:43:15
25
1
700-110a
2
700-006
Engine Oil Make sure the engine oil is at the correct level of the oil filler hole.
1 Oil filler cap 2 Correct level
Recommended engine oil: Recommended oil brand: YAMALUBE Available oil grade: API SE type or higher JASO MA or MB Available viscosity index: 10W-30 or 10W-40 Engine oil quantity: 1.1 L (1.16 US qt, 37.2 oz)
NOTICE
The generator was shipped from the factory with- out engine oil. Do not start the engine for the first time until the oil level has been checked and oil added if necessary.
7P6-F8199-15.indd 25 2021/06/23 11:43:15
26
1
2
3
4
5
Installation 1. Turn the engine switch to 5 (STOP) to prevent
accidental short circuiting.
2. Place the battery on the battery mount tray.
1 Battery 2 Battery mount tray
3. Install the battery mounting rods and battery mounting plate, and then install and tighten the wing nuts.
3 Battery mounting rod 4 Wing nut 5 Battery mounting plate
Battery (For EF7200DE) (See page 49 for more details) This generator is designed to be equipped with a VRLA (Valve Regulated Lead Acid) battery. There is no need to check the electrolyte or to add distilled water.
8
6
7
4. Connect the positive lead (Red) to the positive (+) battery terminal.
6 Screw 7 Positive lead (Red) 8 Positive battery terminal
7P6-F8199-15.indd 26 2021/06/23 11:43:16
27
q
9
0
762-004
we
762-005
w
r
TIP Connect the positive lead (Red) to the positive (+) bat- tery terminal first, then the negative lead (Black) to the negative () battery terminal. Do not reverse these positions.
WARNING
9 Be sure to insulate battery leads to prevent arcing when the battery is not installed.
9 Disconnect the battery charging output lead. Then insulate the connector by folding it back on itself and carefully wrapping it with electri- cal tape to prevent electrical contact with ground (earth) or any other leads.
9 Remove the battery leads from the generator.
w Connector e Battery lead r Electrical tape
5. Connect the negative lead (Black) to the negative () battery terminal.
9 Screw 0 Negative lead (Black) q Negative battery terminal
1
Ground (Earth) Terminal Make sure to ground (earth) the generator. Check SAFETY INFORMATION (See page 4).
1 Ground (earth) terminal
7P6-F8199-15.indd 27 2021/06/23 11:43:16
28
PRE-OPERATION CHECK
WARNING
If any item in the pre-operation check is not work- ing properly, have it inspected and repaired before operating the generator.
The condition of a generator is the owners responsibil- ity. Vital components can start to deteriorate quickly and unexpectedly, even if the generator is unused.
TIP Pre-operation checks should be made each time the generator is used.
Pre-Operation Check Fuel (See page 23) 9 Check fuel level in fuel tank. 9 Refuel if necessary.
Fuel Line 9 Check fuel hose for crack or damage. 9 Replace if necessary.
Engine Oil (See page 25) 9 Check oil level in engine. 9 If necessary, add recommended oil to specified
level. 9 Check generator for oil leakage.
Abnormal Running Conditions 9 If any abnormal running conditions are observed,
please consult a Yamaha dealer.
7P6-F8199-15.indd 28 2021/06/23 11:43:16
29
OPERATION
WARNING
9 Never operate the engine in a closed area or it may cause unconsciousness and death within a short time. Operate the engine in a well ven- tilated area.
9 Before starting the engine, do not connect any electric devices.
9 Clean dust, dirt or water off the receptacle before use.
NOTICE
The generator was shipped from the factory with- out engine oil. Do not start the engine for the first time until the oil level has been checked and oil added if necessary.
Starting The Engine 1. Turn the AC switch (N.F.B.) and economy control
switch to 3 (OFF).
1 3 (OFF)
AC switch (N.F.B.) Economy control switch
705-0372
3
1
B
2. Turn the fuel cock lever to ON.
2 ON
3. Turn the engine switch to 7 (ON).
3 7 (ON)
11
A
7P6-F8199-15.indd 29 2021/06/23 11:43:16
30
5
4. Turn the choke lever to 1.
4 Choke lever
TIP The choke is not required to start a warm engine. Turn the choke lever to the original position.
4
Electric Starting (For EF7200DE): 5. Push the starter switch to start the engine.
5 Starter switch
NOTICE
9 Take your hand off the switch immediately after the engine starts.
9 If the engine fails to start, release the switch, wait a few seconds, then try again. Each attempt should be as short as possible to pre- serve the battery. Do not crank the engine more than 5 seconds on any one attempt.
7P6-F8199-15.indd 30 2021/06/23 11:43:16
31
Manual Starting: 5. Grasp the recoil starter handle and pull slowly until
resistance is felt. Give the starter handle and rope a short, brisk pull to start the engine.
WARNING
Be careful when using recoil starter. In rare cases, the recoil starter handle can be drawn back quickly by the engine kickback.
NOTICE
9 Pull the recoil starter handle straight out. Pulling at an angle could damage the recoil starter rope or other generator parts.
9 Do not allow the starter handle and rope to snap back after starting; return it gently to its original place. Letting go of the handle while the starter rope is extended will allow the recoil starter to rewind rapidly, which can cause damage to the generator.
9 Grasp the carrying handle firmly to prevent the generator from falling over when pulling the recoil starter.
TIP Soon after the purchase or after draining the fuel from the carburetor with the drain screw, the fuel will not be supplied to the entire starting system automatically. Thus, the recoil starter handle may have to be pulled a few times until the engine starts.
7P6-F8199-15.indd 31 2021/06/23 11:43:16
32
6
6. When pushing the starter switch or pulling the recoil starter handle, make sure that both the red and orange indicators are flashing.
NOTICE
If either of them does not flash, consult a Yamaha dealer since the CO SENSOR system is most likely malfunctioning.
7. After the engine starts, warm up the engine until the engine does not stop when the choke lever is returned to the original position.
6 Original position
Stopping The Engine TIP After the engine is stopped the engine cannot be restarted for approximately 15 seconds.
1. Turn off any electric devices.
2. Turn the AC switch (N.F.B.) and economy control switch to 3 (OFF).
1 3 (OFF)
AC switch (N.F.B.)
Economy control switch
11
A
1
B
7P6-F8199-15.indd 32 2021/06/23 11:43:17
33
705-038d
33
5. Turn the fuel cock lever to OFF.
3 OFF
2
3. Disconnect any electric devices.
4. Turn the engine switch to 5 (STOP).
2 5 (STOP)
7P6-F8199-15.indd 33 2021/06/23 11:43:17
34
1. Start the engine.
2. Plug into AC receptacle.
3. Make sure the voltage/hour meter indicates the rated voltage.
If the voltage/hour meter does not indicate the rated voltage (i.e., when using an extension cord, etc.), use the voltage adjuster to adjust the output voltage to the rated voltage.
1 Voltage/hour meter 2 Rated voltage
1 2
000-000
Connection Alternating Current (AC)
WARNING
Be sure any electric devices are turned off before plugging them in.
NOTICE
9 Be sure all electric devices including the lines and plug connections are in good condition before connection to the generator.
9 Be sure the total load is within generator rated output.
9 Be sure the receptacle load current is within receptacle rated current.
TIP 9 Make sure to ground (earth) the generator. When the electric device is grounded, be sure to
ground the generator, too. 9 The power output lead of the portable generator
(stator winding) is insulated from the frame and ground pin of the AC receptacles.
Therefore, an electric device that requires ground- ing through the AC receptacle when plugged in to one of the output leads might not operate correct- ly.
7P6-F8199-15.indd 34 2021/06/23 11:43:17
35
3A
2
240V
120V
120V
GR
W X
G Y
4. Turn the AC switch (N.F.B.) and economy control switch to I (ON) and turn on any electric devices.
3 I (ON)
AC 120 V can be used.
3
C
TIP Turn the voltage adjuster clockwise or counterclock- wise to increase or decrease output voltage.
2 Voltage adjuster
33B AC 120 V and 240 V can be used.
Economy control switch
NOTICE
Reduce the load to the specified generator rated output if the AC switch (N.F.B.) turns off. If it turns off again, consult a Yamaha dealer.
TIP 9 The 4-blade plug receptacle can supply both
120 V and 240 V power sources. 9 The economy control switch must be turned to 3
(OFF) to increase engine speed to rated r/min when:
- using a load of 0.8 A or less. - supplying AC 120 V only from W with X.
7P6-F8199-15.indd 35 2021/06/23 11:43:17
36
4
A
4
4
B
5. Turn the individual AC switch (N.F.B.) to I (ON).
4 I (ON)
Individual AC switch (N.F.B.) for AC receptacle
Individual AC switch (N.F.B.) for G. F. C. I. receptacle
7P6-F8199-15.indd 36 2021/06/23 11:43:18
37
Application Range When using the generator, make sure the total load is within rated output of a generator. Otherwise, generator damage may occur.
AC
Power factor 1 0.80.95 0.40.75
(Efficiency 0.85)
6000 W 4800 W 2040 W
Approximate Wattages of Common Tools or Equipment
Tools Wattage Equipment Wattage
Chain saw 10001800 Space heater 1500
Circular saw 12001600 Hot plate 1200
Sanders 2501500 Crock pot 1200
Router 1001500 Television 250
Leaf blower 10001400 Lights 250
Shop vacuum 7001400 Fan 100
Drill (depends on size) 2501200
String trimmer 6001100
Paint sprayer 5001000
Miter saw 5001000
Hedge clippers 3001000
Planer 300900
TIP 9 means below. 9 Application wattage indicates when each device is used by itself.