The Parkside PKO 500 A1, identified by model number 3906128974 and IAN 292195, is a versatile air compressor designed for various domestic and light industrial applications. With a robust build, this compressor features a powerful motor that provides a maximum pressure output of 8 bar, making it suitable for tasks such as inflating, nailing, stapling, and paint spraying. The compressor operates with a 1.5 kW electric motor, ensuring efficient performance while maintaining energy efficiency.

Its tank capacity is 24 liters, offering ample air reserve to sustain prolonged operations without frequent interruptions for pressure recovery. The PKO 500 A1 is equipped with a direct-drive pump, which minimizes maintenance needs and enhances reliability. It delivers an air intake capacity of approximately 260 liters per minute, ensuring rapid pressurization and effective tool operation.

This model incorporates a pressure gauge and a regulator for precise control over the output pressure, allowing users to adjust according to specific requirements of different tools. Additionally, the compressor is designed with a thermal overload protection system to prevent overheating, thereby extending the lifespan of the equipment. For ease of mobility, the PKO 500 A1 includes transport wheels and a handle, facilitating easy movement across worksites or garages.

The Parkside PKO 500 A1 is constructed with durable materials, ensuring long-term resilience against wear and tear. Its compact dimensions provide convenient storage while not in use. This compressor is an ideal choice for DIY enthusiasts and hobbyists seeking a reliable and powerful air supply solution for a variety of pneumatic tools and projects.

Parkside PKO 500 A1 3906128974 IAN 292195 Compressor F.A.Q.

How do I properly set up the Parkside PKO 500 A1 compressor for first-time use?

To set up the Parkside PKO 500 A1 compressor, first ensure that the unit is placed on a stable, level surface. Check that the power supply matches the compressor's voltage requirements. Attach the air hose to the outlet and secure it tightly. Finally, confirm that all safety features, such as the pressure relief valve, are functioning correctly before turning it on.

What is the recommended maintenance schedule for the Parkside PKO 500 A1 compressor?

Perform maintenance every 50 hours of operation. This includes checking and cleaning the air filter, inspecting for air leaks, and ensuring that all moving parts are lubricated. Additionally, drain the condensation from the tank after each use to prevent rusting.

How can I troubleshoot if the compressor does not start?

If the compressor does not start, first check the power supply and ensure the unit is plugged in. Verify that the circuit breaker has not tripped. Inspect the pressure switch and reset it if necessary. Lastly, ensure that the safety switch is not engaged.

What should I do if the compressor is not building enough pressure?

Check for any visible air leaks in the hose or fittings. Make sure the intake filter is clean and not obstructed. Inspect the pressure regulator to ensure it is set correctly. If the problem persists, the issue may lie with the compressor's internal components, and professional servicing might be required.

How do I safely transport the Parkside PKO 500 A1 compressor?

Ensure the compressor is turned off and unplugged. Release any air pressure in the tank by opening the drain valve. Secure the compressor to prevent movement, using straps if necessary, and transport it in an upright position to avoid oil leakage.

Can I use the compressor for painting tasks?

Yes, the Parkside PKO 500 A1 compressor can be used for painting tasks. Ensure that you use the appropriate spray gun and adjust the pressure settings according to the paint manufacturer's recommendations. Regularly clean the equipment after use to maintain performance.

What type of oil should be used for the Parkside PKO 500 A1 compressor?

Use a high-quality, non-detergent compressor oil. The manufacturer's manual specifies the correct oil grade, usually SAE 30 or its equivalent. Regular oil checks and changes are essential for optimal performance.

How do I adjust the pressure settings on the Parkside PKO 500 A1 compressor?

The pressure settings can be adjusted using the pressure regulator knob. Turn the knob clockwise to increase the pressure and counterclockwise to decrease it. Always monitor the pressure gauge to ensure the settings are within the desired range for your application.

What safety precautions should be taken when operating the compressor?

Always wear safety goggles and hearing protection when operating the compressor. Ensure the area is well-ventilated, and avoid overloading the electrical circuit. Do not modify any safety features, and regularly inspect the unit for damage or wear.

How do I resolve issues with excessive noise from the compressor?

Check that the compressor is on a stable surface. Tighten any loose components and inspect for worn bearings or motor issues. If the noise persists, professional servicing may be necessary to address internal problems.