Parkside PKO 270 A2 3906118978 IAN 275673 Compressor Specification

The Parkside PKO 270 A2 3906118978 IAN 275673 Compressor is a versatile and robust air compression unit designed for both professional and home use. It features a powerful 1.8 kW motor that delivers a maximum pressure of 10 bar, allowing it to efficiently power a variety of pneumatic tools and applications. With a 24-liter tank capacity, this compressor provides a reliable air supply for tasks ranging from inflating tires to operating airbrushes and nail guns.

The compressor is equipped with an oil-lubricated pump, enhancing its durability and longevity. It boasts an impressive air intake capacity of 270 liters per minute, making it suitable for continuous operation without overheating. The PKO 270 A2 includes an integrated pressure gauge and a pressure regulator that ensures precise control over output pressure, catering to diverse operational requirements. Its quick coupling system facilitates easy and fast connection changes between tools, enhancing workflow efficiency.

For user convenience, the compressor is mounted on sturdy wheels and features a handle for easy maneuverability, allowing it to be transported effortlessly across different work sites. Safety is prioritized with a built-in overload protection system that prevents potential damage from overheating, ensuring a reliable performance under demanding conditions. The unit's compact design and robust construction make it a practical addition to any workshop or garage, combining functionality with ease of use. Its maintenance requirements are minimal, largely due to the oil-lubricated design, which also contributes to quieter operation compared to oil-free alternatives. Overall, the Parkside PKO 270 A2 compressor is a well-rounded, high-performance tool tailored for efficient and reliable operation in various settings.

Parkside PKO 270 A2 3906118978 IAN 275673 Compressor F.A.Q.

How do I properly start the Parkside PKO 270 A2 compressor?

To start the Parkside PKO 270 A2 compressor, first ensure it is placed on a flat, stable surface. Check that all connections are secure and that the power switch is in the "Off" position. Plug the compressor into a suitable power outlet, then turn the power switch to the "On" position. Allow the compressor to build up pressure before connecting any tools.

What maintenance steps should I follow for the Parkside PKO 270 A2?

Regular maintenance for the Parkside PKO 270 A2 includes checking and cleaning the air filter, draining condensation from the tank, inspecting hoses for wear and tear, and periodically checking the oil level if applicable. Always ensure the compressor is turned off and unplugged before performing maintenance.

How can I troubleshoot if the compressor is not building pressure?

If the compressor is not building pressure, check for air leaks in the hoses or connections. Ensure the drain valve is closed securely. Inspect the air filter for clogs and clean it if necessary. Verify that the pressure switch is functioning correctly and that the compressor is receiving adequate power.

What should I do if the compressor overheats during operation?

If the compressor overheats, turn it off immediately and allow it to cool down. Ensure it is placed in a well-ventilated area to prevent overheating. Check the air filter for obstructions and ensure the oil level is adequate, if applicable. Avoid running the compressor for extended periods without breaks.

How often should I drain the condensation from the tank?

It is recommended to drain the condensation from the tank after each use to prevent rust and corrosion. Ensure the compressor is turned off and depressurized before opening the drain valve to release any accumulated moisture.

Can I use the Parkside PKO 270 A2 for spray painting?

Yes, the Parkside PKO 270 A2 can be used for spray painting. Ensure you use the appropriate spray gun and adjust the pressure settings according to the paint manufacturer's recommendations. Always wear protective gear and work in a well-ventilated area.

How do I check the oil level in the compressor, if applicable?

To check the oil level, ensure the compressor is on a flat surface and turned off. Locate the oil sight glass or dipstick. The oil level should be within the marked range. If the level is low, add the recommended compressor oil until it reaches the correct level.

What precautions should I take when storing the compressor?

Before storing the compressor, drain any moisture from the tank and disconnect all hoses and tools. Store it in a dry, cool place away from direct sunlight and corrosive materials. Ensure it is covered or placed in a dust-free environment to prevent debris accumulation.

Why is my compressor making unusual noise during operation?

Unusual noise may be due to loose components, worn bearings, or a malfunctioning pressure relief valve. Inspect the compressor for loose bolts or fittings and tighten them if necessary. If the noise persists, consult the user manual or a professional technician for further inspection.

How can I ensure optimal performance of my Parkside PKO 270 A2 compressor?

To ensure optimal performance, regularly perform maintenance checks, keep the air filter clean, and ensure all connections are secure. Use the compressor in a suitable environment and avoid overloading it with tasks beyond its capacity. Follow the manufacturer's guidelines for operation and maintenance.