Mitsubishi FR-E700 FR-E720-0.1KNC Instruction Manual
![Mitsubishi FR-E700 FR-E720-0.1KNC Inverter manual cover](/images/AHwOAxqsVcVTwzvCRRtimrsD/thumbs/thumb175x175.webp)
To connect the Mitsubishi FR-E720-0.1KNC inverter to a PLC, use the RS-485 communication interface. Ensure that the communication parameters on both devices, such as baud rate and data bits, are correctly configured to match each other. Refer to the inverter's manual for detailed wiring instructions and PLC programming requirements.
Common fault codes for the FR-E720-0.1KNC include E.OC1 (overcurrent during acceleration), E.OL1 (overload), and E.UVT (undervoltage). To resolve these issues, check for proper motor connections, ensure the load is within rated capacity, and verify that the power supply voltage is stable and adequate. Refer to the troubleshooting section of the inverter manual for more specific guidance.
To reset the FR-E720-0.1KNC inverter after a fault trip, you can either use the reset button on the keypad or cycle the power to the inverter. Ensure that the fault condition has been resolved before resetting the inverter to prevent further trips.
Regular maintenance for the FR-E720-0.1KNC inverter includes checking the cooling fan for proper operation, inspecting connections for signs of wear or corrosion, cleaning the air vents to ensure adequate cooling, and verifying that all parameter settings are correct and have not been altered unintentionally.
To change the acceleration and deceleration times on the FR-E720-0.1KNC inverter, access the parameter settings via the keypad. Adjust parameters Pr.7 (acceleration time) and Pr.8 (deceleration time) to the desired values. Make sure to save the changes before exiting the parameter setting mode.
The FR-E720-0.1KNC inverter is designed for use with three-phase motors. It is not recommended to use this inverter with single-phase motors as it may lead to improper operation or damage.
To configure the FR-E720-0.1KNC inverter for remote operation, set parameters Pr.79 (operation mode) and Pr.128 (remote ON/OFF control) according to your system requirements. Ensure that the remote control wiring is correctly connected to the terminal block.
Currently, the FR-E720-0.1KNC inverter does not support firmware updates via conventional methods. For any functionality upgrades, consult Mitsubishi Electric customer support or a certified service technician.
To monitor the output frequency in real-time on the FR-E720-0.1KNC inverter, use the digital display on the inverter's keypad. Alternatively, you can connect the inverter to a monitoring system via RS-485 and use Mitsubishi’s software tools for real-time data tracking.
If the FR-E720-0.1KNC inverter is not starting the motor, check the following: ensure that all input power terminals are connected correctly, verify that the run command is properly configured, and check for any active fault codes. If there is no fault indicated, inspect the motor wiring and settings.