Mitsubishi FR-A700 FR-A720-0.4K Instruction Manual
![Mitsubishi FR-A700 FR-A720-0.4K Inverter manual cover](/images/ybsawRQLmderQSiGMNlJUqJI/thumbs/thumb175x175.webp)
To perform a factory reset, enter the inverter's parameter setting mode, navigate to parameter 79, and set it to 1. Confirm the operation to reset all parameters to factory settings.
Ensure power is disconnected before wiring. Connect the input power to the R, S, T terminals and the motor to the U, V, W terminals. Verify connections with the manual for specific wiring details.
Check the power supply voltage and ensure it is within the inverter's rated range. Inspect the deceleration time setting and increase it if necessary to prevent regenerative overvoltage.
Regularly clean the cooling fan and heat sink to prevent overheating. Check connections and tighten any loose screws. Inspect for any signs of wear or damage.
Access the parameter setting mode and adjust parameter 2 (frequency setting) to your desired value. Ensure that the motor is compatible with the set frequency.
Verify that the communication settings match between the inverter and PLC. Check the wiring and replace any faulty cables. Confirm that the correct protocol is selected.
Refer to the Mitsubishi Electric website for the latest firmware version. Follow the instructions provided in the update guide, using a USB connection and the specified software tool.
E.OC1 indicates an overcurrent during acceleration. Reduce the load or increase the acceleration time to prevent excessive current. Check motor and mechanical load for issues.
Ensure proper ventilation and avoid operating the inverter in extreme temperatures. Regularly clean and inspect the unit, and follow the recommended maintenance schedule.
The FR-A720-0.4K inverter is designed for three-phase motors. Using it with a single-phase motor is not recommended and may lead to malfunction or damage.