Mitsubishi A800 FR-A800-LC Instruction Manual
![Mitsubishi A800 FR-A800-LC Inverter manual cover](/images/ESluOZrmVZTWDuDvsDJjRoyv/thumbs/thumb175x175.webp)
To perform a factory reset on the Mitsubishi A800 FR-A800-LC Inverter, navigate to the parameter settings menu, and set parameter "Pr. 79" to "9999". This will reset the inverter to its default factory settings. Ensure to back up any important configurations before proceeding.
To troubleshoot an overcurrent fault, first check for any short circuits or grounding issues in the motor and wiring. Verify that the motor is not overloaded and that the settings for the motor current under parameter "Pr. 9" are correct. If necessary, adjust the acceleration and deceleration times.
To extend the lifespan of your inverter, ensure it is installed in a well-ventilated area to prevent overheating. Regularly clean the heat sink and fan to remove dust and debris. Periodically inspect connections for tightness and monitor for any unusual noise or vibration.
Regular maintenance practices include inspecting and cleaning the cooling fan and heat sink, checking for loose connections, and ensuring that the environmental conditions such as temperature and humidity are within the specified range. Conduct a visual inspection for any signs of wear or damage.
To configure the inverter for energy-saving mode, access the parameter settings and adjust the "Pr. 60" parameter to enable the energy-saving operations. This mode optimizes the motor performance and reduces energy consumption based on the load requirements.
An E6 error code indicates a communication error. Check the communication cable connections for any loose or damaged wires. Verify that the communication settings in the inverter match those of the connected device. Restart the inverter and the connected device if necessary.
To control a motor via external signals, configure the input terminals through parameters such as "Pr. 178" for terminal assignment. Connect the control signals to the designated terminals and ensure proper voltage levels are used. Adjust the settings to match the control logic required.
Yes, the FR-A800-LC Inverter can be used for a multi-motor setup. However, ensure that the combined load does not exceed the inverter's capacity. Use individual protection and control devices for each motor, and configure the inverter's parameters to accommodate multiple motors.
To update the firmware, download the latest firmware version from the Mitsubishi Electric website. Connect the inverter to a computer via the USB or communication port. Use the provided software tool to upload the new firmware, following the manufacturer's instructions carefully.
To minimize electrical noise interference, use shielded cables for all connections and ensure they are properly grounded. Maintain a separation between power and signal cables. Install line reactors or EMI filters if necessary, and follow the installation guidelines provided by Mitsubishi.