Mitsubishi Electric FX 4AD TC User's Guide
![Mitsubishi Electric FX 4AD TC manual cover](/images/db50b0645b9e465c65638e4d/thumbs/thumb175x175.webp)
To connect the FX 4AD TC module to a Mitsubishi PLC system, first ensure the PLC is powered off. Mount the module on the DIN rail next to the PLC and connect the expansion bus cable from the PLC to the module. Finally, power on the PLC and configure the module settings in the PLC software.
The FX 4AD TC module supports four analog input channels and can accept thermocouple types K, J, T, E, R, S, B, and N. The input range varies depending on the type of thermocouple connected.
First, verify that the thermocouples are properly connected and in good condition. Check the wiring for any loose connections or faults. Ensure that the correct thermocouple type is configured in the module settings. Finally, calibrate the module if necessary.
To calibrate the FX 4AD TC module, use the calibration function in the PLC software. Follow the on-screen instructions to input known temperature values and adjust the module accordingly. Calibration might require a reference thermocouple or a temperature calibrator.
In the PLC software, navigate to the hardware configuration section and select the FX 4AD TC module from the list of available modules. Set the channel parameters such as input type and scaling according to your application's requirements.
The FX 4AD TC module is designed for industrial environments, but it should be used within the specified temperature and humidity ranges. For extreme environments, additional protective measures might be necessary to ensure reliability.
To update the firmware of the FX 4AD TC module, download the latest firmware version from the Mitsubishi Electric website. Use the PLC software to upload the firmware to the module following the provided instructions. Ensure the system is backed up before proceeding.
Regular maintenance for the FX 4AD TC module includes checking connections for wear or corrosion, ensuring the module is free from dust and debris, and verifying accurate readings through periodic calibration.
To protect the FX 4AD TC module from electrical noise, use shielded cables for connections and ensure the shield is properly grounded. Additionally, avoid running signal cables parallel to power cables to minimize interference.
The maximum cable length for thermocouple connections to the FX 4AD TC module depends on the type of thermocouple and the installation environment. Generally, it is recommended to keep the cable length as short as possible to reduce signal degradation.