Flir Extech TM55 Thermometer Specification
Flir Extech TM55 Thermometer F.A.Q.
How do I calibrate the Flir Extech TM55 thermometer?
To calibrate the Flir Extech TM55 thermometer, follow these steps: 1) Ensure the thermometer is turned off. 2) Use a certified calibration source to provide a known temperature. 3) Turn the thermometer on while holding the calibration button. 4) Adjust the reading using the calibration screw until it matches the calibration source value. 5) Save the settings and exit calibration mode.
What should I do if the TM55 thermometer is not turning on?
First, check the battery compartment to ensure the batteries are correctly installed and have sufficient charge. Replace the batteries if necessary. If the issue persists, inspect the device for any visible damage. If no damage is found, contact Flir customer support for further assistance.
Can the TM55 thermometer be used for both indoor and outdoor measurements?
Yes, the Flir Extech TM55 thermometer is designed for both indoor and outdoor use. However, it's important to avoid direct exposure to extreme weather conditions to ensure accurate readings and prolong the device's lifespan.
How do I replace the batteries in the Flir Extech TM55 thermometer?
To replace the batteries in the TM55 thermometer, gently slide open the battery compartment cover located on the back of the device. Remove the old batteries and replace them with new ones, ensuring correct polarity. Close the compartment securely before turning the device back on.
What is the recommended maintenance schedule for the TM55 thermometer?
Regular maintenance for the TM55 thermometer includes monthly battery checks, calibration every six months, and cleaning the sensor area with a soft cloth as needed. Store the device in a dry, dust-free environment when not in use to maintain optimal performance.
Why am I getting inconsistent readings with the TM55 thermometer?
Inconsistent readings may be caused by several factors. Ensure the sensor is clean and free of obstructions. Check for proper calibration, and recalibrate if necessary. Verify that the thermometer is used within its specified operating conditions and away from electromagnetic interference.
How do I switch between Celsius and Fahrenheit on the TM55 thermometer?
To switch between Celsius and Fahrenheit on the TM55 thermometer, enter the settings menu by pressing the mode button. Navigate to the temperature unit option and select the desired unit. Save the changes and exit the menu.
What should I do if the display screen of the TM55 thermometer is not functioning properly?
If the display screen is malfunctioning, first perform a reset by removing and reinserting the batteries. If the issue persists, examine the screen for visible damage. For technical support, contact Flir customer service for repair or replacement options.
Can the TM55 thermometer measure surface temperature?
Yes, the Flir Extech TM55 thermometer is capable of measuring surface temperature. Ensure the infrared sensor is aimed directly at the surface and that the measurement distance is within the specified range for accurate readings.
What is the effective measurement range of the TM55 thermometer?
The Flir Extech TM55 thermometer has an effective measurement range of -50 to 550 degrees Celsius (-58 to 1022 degrees Fahrenheit). Always refer to the product manual for specific guidelines and ensure measurements are taken within this range for accuracy.