Arneg Korinthos 2 Installation and Use Manual
![Arneg Korinthos 2 Refrigerated Cabinet manual cover](/images/uvgEqPSZagKZyPPwCTWNMtIF/thumbs/thumb175x175.webp)
To clean the Arneg Korinthos 2 Refrigerated Cabinet, first disconnect the power supply. Use a soft cloth and a mild detergent to clean the surfaces, avoiding abrasive materials that can scratch the surface. Rinse with water and dry thoroughly before reconnecting the power.
The recommended temperature setting for the Arneg Korinthos 2 Refrigerated Cabinet is between 2°C and 5°C, depending on the type of products being stored. Always refer to the manufacturer's guidelines for specific product requirements.
If the cabinet is not cooling properly, check for blockages in the airflow, ensure the doors are sealing correctly, and verify that the condenser coils are clean. If issues persist, consult a professional technician for further diagnosis.
Regular maintenance includes cleaning the condenser coils monthly, checking door seals for damage, and inspecting the refrigerant levels. It's also important to ensure the cabinet is level and situated in a well-ventilated area.
To adjust the shelves, first remove the products. Then, gently lift the shelf and reposition the shelf clips at the desired height. Ensure the shelf is level and securely positioned before replacing the products.
Excessive frost buildup can be caused by frequent door openings or faulty door seals. Defrost the cabinet by turning off the unit and allowing the frost to melt. Check door seals for damage and ensure the cabinet is not overloaded.
Yes, you can replace the interior light bulb by first disconnecting the power. Remove the light cover, unscrew the old bulb, and replace it with a new one of the same type and wattage. Reattach the cover and reconnect the power.
Noisiness can be caused by the cabinet not being level, loose components, or the compressor working too hard. Ensure the cabinet is level, tighten any loose parts, and check for obstructions to airflow that could cause the compressor to overwork.
To change the temperature settings, access the digital thermostat panel, press the menu button, and use the up or down arrows to adjust the temperature. Confirm the new setting by pressing the confirm button. Refer to the user manual for detailed instructions.
Water pooling can occur due to a blocked drain or humidity issues. Check the drainage tube for blockages and clear any debris. Also, ensure the cabinet is in a low-humidity environment and that door seals are intact.