Viessmann Vitorond 100 Hydrostat 3250-Plus Instructions Supplement
![Viessmann Vitorond 100 Hydrostat 3250-Plus Boiler manual cover](/images/ReQDfgUoPMNDIUoTOXDJbGFZ/thumbs/thumb175x175.webp)
To start the boiler, ensure that the power supply is connected and the water supply is turned on. Then, set the desired temperature on the Hydrostat 3250-Plus control panel and press the power button.
Check the thermostat settings and ensure they are correct. Verify that the boiler pressure is within the recommended range (1.0 to 1.5 bar). If the issue persists, inspect and clean the burner and heat exchanger.
Regular maintenance includes checking the pressure gauge, bleeding radiators, cleaning the burner, inspecting the flue system, and scheduling an annual professional service.
Error code 'F4' indicates a flame failure. Check the gas supply, ensure the gas valve is open, and inspect the ignition system for faults. Reset the boiler after addressing the issue.
Use the control dial on the Hydrostat 3250-Plus to set the desired temperature. The recommended range for hot water is between 60-70°C to ensure both efficiency and safety.
Noises can be caused by air in the system, a faulty pump, or sediment build-up in the heat exchanger. Bleed the radiators and check the pump. If noises persist, consult a technician.
Press the reset button on the Hydrostat 3250-Plus control panel. Hold it for a few seconds until the display resets. If the fault continues, further investigation may be needed.
Ensure the system is protected against freezing by checking the antifreeze levels. Maintain the heating at a low setting if the property is unoccupied to prevent pipes from freezing.
Check the pressure gauge monthly. The ideal range is between 1.0 and 1.5 bar. If the pressure is low, top up the system using the filling loop.
Homeowners can perform basic tasks such as checking and adjusting pressure, bleeding radiators, and cleaning accessible parts. For all other maintenance, consult a qualified technician.