Viessmann Solar-Divicon DN25B Installation Instructions
![Viessmann Solar-Divicon DN25B Accessory manual cover](/images/kYaOyJijvYCsUTiMLzzYZJqm/thumbs/thumb175x175.webp)
To install the Viessmann Solar-Divicon DN25B, first ensure that all system components are compatible. Mount the unit securely on a flat surface, connect the solar circuit, and then connect the heat exchanger circuit. Follow the manufacturer's manual for specific installation steps and safety precautions.
To check the system pressure, attach a pressure gauge to the designated valve on the Solar-Divicon DN25B. Open the valve to read the pressure, ensuring it falls within the specified range in the user manual. Adjust the pressure as necessary by adding or releasing fluid.
Regular maintenance should be performed annually. This includes checking for leaks, inspecting seals and connections, testing system pressure, and cleaning any filters. Follow the detailed maintenance schedule provided in the manual for optimal performance.
Unusual noises could be due to air trapped in the system or a failing component. First, bleed the system to remove any air. If the noise persists, inspect the pump and valves for wear or damage and replace if necessary.
Check the temperature settings and ensure they are correctly configured. Inspect the flow rate and adjust if necessary. Verify that the temperature sensors are functioning correctly and replace them if defective.
Use a solar-specific heat transfer fluid as recommended by Viessmann. This fluid is typically a mixture of water and glycol, designed for high efficiency and longevity. Always check the manual for the recommended type and concentration.
Yes, the Solar-Divicon DN25B can be integrated with other Viessmann solar components. Ensure compatibility by consulting the product specifications and installation guides provided by Viessmann.
Signs of a leak include drops in system pressure, visible fluid around connections or components, and reduced system efficiency. Regularly inspect the system for these signs and address any issues immediately.
First, isolate the pump by shutting off the relevant valves. Safely drain the system if necessary. Disconnect the electrical connections, remove the faulty pump, and install a new one. Reconnect the electrical connections and test the system for proper operation.
To winterize the system, ensure that the heat transfer fluid has the correct antifreeze concentration for your climate. Check all insulation and weather seals, and perform a system check to ensure all components are functioning properly before the onset of cold weather.