Toolson MK180-3 3906134915 Instruction Manual

Toolson MK180-3 3906134915 Compressor manual cover
Pages 136
Year 2018
Language(s)
Czech cs
German de
English en
Estonian et
Finnish fi
French fr
Croatian hr
Hungarian hu
Italian it
Lithuanian lt
Norwegian Nynorsk; Nynorsk, Norwegian nn
Slovak sk
Slovenian sl
Swedish sv
Danish dk
Latvian lv
Dutch; Flemish nl
Polish pl

Toolson MK180-3 3906134915 Compressor Specification

The Toolson MK180-3 3906134915 Compressor is a robust and efficient solution designed for various pneumatic applications. Engineered for reliability and high performance, this compressor is equipped with a 180-liter tank that ensures an ample supply of compressed air for extended use. It operates on a three-phase 400V electrical supply, which is ideal for heavy-duty industrial environments, providing consistent power for demanding tasks.

The compressor features a powerful motor that delivers an output of 3 horsepower, enabling a maximum pressure of 10 bar. This allows it to efficiently handle a wide range of applications, from powering pneumatic tools to inflating tires and more. The Toolson MK180-3 employs a direct-drive mechanism, enhancing its efficiency and reducing maintenance requirements by eliminating the need for belts and pulleys.

For user convenience, the compressor is equipped with an easy-to-read pressure gauge and a quick-release coupling, facilitating straightforward operation and quick connections. The unit is designed with a compact footprint, allowing for flexible installation and space-saving storage. Additionally, it includes an integrated cooling system that ensures optimal operating temperatures, thereby extending the lifespan of the compressor.

Safety features are also a priority, with the inclusion of an automatic shut-off system that activates when maximum pressure is reached, preventing overloading and potential damage. The Toolson MK180-3 is built with durable materials, ensuring longevity and reliable performance even in challenging conditions. Its design reflects a balance between functionality and user-friendliness, making it a preferred choice for both professional workshops and industrial settings.

Toolson MK180-3 3906134915 Compressor F.A.Q.

How do I properly set up my Toolson MK180-3 3906134915 Compressor for first use?

Ensure the compressor is placed on a flat, stable surface. Check that all components, such as hoses and fittings, are securely connected. Fill the oil reservoir with the recommended oil type and level, then connect the compressor to a suitable power source. Perform a test run without load to check for any irregular noises or leaks.

What maintenance steps should I follow for the Toolson MK180-3 Compressor?

Regularly check and change the oil every 500 working hours or as recommended. Inspect air filters monthly and clean or replace them as necessary. Check for leaks in hoses and fittings, and ensure all connections are tight. Drain the tank of moisture after each use to prevent rusting.

How can I troubleshoot a Toolson MK180-3 Compressor that won't start?

First, check the power supply and ensure the compressor is plugged into a functioning outlet. Verify that the circuit breaker has not tripped. Inspect the compressor's pressure switch and reset it if necessary. If the compressor still won't start, check the motor capacitor and replace it if faulty.

What should I do if the compressor is not building sufficient pressure?

Inspect for air leaks around hoses and fittings and seal any leaks found. Check the intake filter for blockages and clean or replace it if necessary. Ensure the tank drain valve is closed tightly. If the problem persists, inspect the pressure regulator for malfunctions.

Why is my Toolson MK180-3 Compressor making excessive noise?

Excessive noise can be caused by loose components, so check and tighten all bolts and fittings. Inspect the compressor's mounting and ensure it is stable and secure. If the noise continues, check the motor and pump for wear or damage, and consult a professional if necessary.

How often should I replace the air filter on my compressor?

The air filter should be checked monthly for dirt and debris. Replace the filter every 3 months or more frequently if operating in a dusty environment to ensure optimal performance and longevity of the compressor.

Can I use synthetic oil in my Toolson MK180-3 Compressor?

Yes, synthetic oil can be used in the Toolson MK180-3 Compressor, provided it meets the manufacturer's specifications. Synthetic oil can offer better performance in extreme temperatures and longer intervals between changes.

What safety precautions should I follow when using the Toolson MK180-3 Compressor?

Always wear appropriate personal protective equipment, such as safety glasses and ear protection. Ensure the workspace is well-ventilated and clear of any flammable materials. Never exceed the recommended pressure ratings, and always disconnect the power supply before performing maintenance.

How can I prevent my compressor from overheating during extended use?

Ensure the compressor is in a well-ventilated area to allow for adequate cooling. Avoid operating the compressor continuously without breaks. Check and clean the cooling fins regularly to prevent dust accumulation, which can impede heat dissipation.

What should I do if the compressor's motor keeps tripping the circuit breaker?

Check if the circuit is overloaded and ensure that the compressor is the only appliance on that circuit. Verify that the extension cord (if used) is of adequate gauge and length. Inspect the motor for overheating or electrical faults, and consult a technician if the issue persists.