Sealey MC105 Instruction Manual
![Sealey MC105 Tester manual cover](/images/MwsWncLDBgSzabQvNRakVexU/thumbs/thumb175x175.webp)
To perform a continuity test, first ensure the device is off. Connect the test leads to the tester, then set the selector to the continuity mode. Touch the test probes to the circuit or component you want to test. If the circuit is continuous, the tester will emit a beep sound.
If the tester does not power on, check the battery compartment to ensure the batteries are installed correctly and have enough charge. Replace the batteries if necessary. Also, inspect the power button for any damage or obstruction.
To measure DC voltage, connect the red test lead to the VΩ socket and the black lead to the COM socket. Set the selector to the DC voltage range. Place the probes across the component or circuit, ensuring correct polarity. Read the measurement on the display.
Regularly clean the tester with a soft, dry cloth. Avoid using any chemicals or solvents. Inspect the test leads for signs of wear and replace them if damaged. Store the tester in a dry, cool place when not in use to prevent moisture damage.
The Sealey MC105 Tester is designed primarily for voltage, continuity, and resistance measurements. For measuring AC current, you would require a clamp meter or a multimeter specifically designed for current measurement.
To replace the fuse, first disconnect any test leads. Open the battery compartment and remove the batteries. Locate the fuse holder, remove the blown fuse, and replace it with a new one of the same rating. Reinstall the batteries and secure the compartment.
An "OL" (overload) reading typically indicates that the measurement exceeds the tester's current range capability. Try switching to a higher range setting on the tester to obtain a correct reading.
To measure resistance, connect the test leads to the tester and set the selector to the resistance (Ω) mode. Touch the probes across the component or circuit part to be measured. The resistance value will be displayed on the screen.
Always ensure the tester is set to the correct measurement type and range before use. Do not exceed the specified input limits, and use the tester in dry conditions to avoid electric shock. Keep fingers behind the probe barriers when taking measurements.
For accurate readings, regularly calibrate the tester according to the manufacturer's instructions. Ensure good contact between test probes and the component being tested, and avoid measuring in conditions with high electromagnetic interference.