Kity MB 25 500250116 3300250716 Operating Instructions
![Kity MB 25 500250116 3300250716 Mortising Machine manual cover](/images/WvEgqfrikCFZuYNqBBnSePJB/thumbs/thumb175x175.webp)
To set up the Kity MB 25 Mortising Machine, begin by assembling the stand and securing the machine to it. Ensure all bolts are tightened and the machine is stable. Connect the dust collection system, and check the power connections. Adjust the chisel and bit alignment according to the manual, and perform a test run to ensure everything is operating smoothly.
Regular maintenance includes cleaning the machine after each use, lubricating moving parts monthly, and checking the alignment of the chisel and bit. Inspect the belts and replace them if they show signs of wear. It's also important to check and tighten any loose bolts periodically.
First, check the power source and ensure the machine is plugged in. Inspect the fuse and replace it if necessary. Examine the power switch and wiring for any damage. If the problem persists, consult a professional technician or contact customer support for further assistance.
Ensure the chisel and bit are sharp and correctly aligned. Check the depth stop and adjust it if necessary. Verify that the workpiece is firmly secured to prevent movement during operation. If issues persist, recalibrate the machine and perform test cuts on scrap wood.
To change the chisel and bit, first disconnect the machine from the power source. Loosen the chisel and bit securing bolts. Carefully remove the old chisel and bit, and insert the new ones, ensuring they are properly aligned. Tighten the securing bolts and reconnect the machine to power.
Always wear safety goggles and hearing protection. Ensure the work area is clean and free of obstructions. Keep hands clear of moving parts and use push blocks or other aids to guide the workpiece. Disconnect the machine from power when making adjustments or performing maintenance.
Ensure the dust collection system is properly connected and that there are no blockages in the hose. Regularly empty the dust bag or container to maintain suction efficiency. Consider upgrading to a more powerful dust collection system if you frequently work with large volumes of material.
Excessive vibration can be caused by an unbalanced chisel and bit, loose components, or an unstable base. Check the alignment and balance of the chisel and bit. Tighten all bolts and ensure the machine is properly secured to the stand. Adjust the base to ensure stability.
To align the chisel and bit, ensure the chisel is square to the table and the bit is centered within the chisel. Use alignment tools as recommended in the manual. Make small adjustments and perform test cuts to verify alignment before proceeding with your project.
If the motor overheats, stop the machine immediately and disconnect it from the power source. Allow it to cool down before inspecting for blockages or mechanical issues. Ensure the ventilation slots are clear of dust and debris. If the problem continues, consult a professional technician.