Ensure the fuel tank is filled and securely attached. Turn the fuel valve slightly open, then use a match or a lighter to ignite at the burner head. Adjust the flame as needed.
The Coleman Pocket II Stove 505 is designed to use white gas, also known as Coleman Fuel, for optimal performance.
Remove the burner cap and gently clean it with a soft brush. You can also use a pin to clear any clogged holes in the burner.
Check the fuel level and ensure the fuel valve is not clogged. Additionally, inspect the generator for any blockages and clean as necessary.
Regularly check and clean the burner, inspect the fuel tank for leaks, and ensure the pump is working smoothly by lubricating it with oil.
No, a yellow flame indicates incomplete combustion. Check for blockages in the burner or incorrect fuel use. The flame should be blue.
Empty the fuel tank, clean the stove thoroughly, and store it in a dry, cool place to prevent corrosion or damage.
Inspect all connections for tightness, check the fuel cap gasket for wear, and replace the pump cup if necessary.
Use the fuel valve to adjust the flame size. Turning it clockwise decreases the flame, while counterclockwise increases it.