To start the generator, ensure the fuel valve is open, the choke is set to the 'start' position, and the engine switch is on. Pull the recoil starter or use the electric start if available.
Use unleaded petrol with a minimum octane rating of 87 for optimal performance. Avoid using fuel with high ethanol content.
Change the oil after the first 20 hours of use, then every 50 hours of operation or annually, whichever comes first. Use SAE 10W-30 oil for best results.
Check the fuel level, ensure the spark plug is not fouled, verify the air filter is clean, and make sure the engine switch is on. If issues persist, consult the manual or a technician.
Ensure the generator is placed on a level surface and away from enclosed spaces. Consider using a noise-reducing enclosure or placing it on a sound-absorbing mat.
No, operating the generator in wet conditions is not safe. Ensure the generator is in a dry, well-ventilated area and protected from any moisture or rain.
For optimal performance, do not exceed 80% of the generator's rated capacity, which is approximately 4.4KVA for continuous use.
Regular maintenance includes checking and changing the oil, cleaning the air filter, inspecting the spark plug, and ensuring all bolts and nuts are tight. Refer to the user manual for detailed instructions.
No, running the generator indoors can lead to dangerous carbon monoxide buildup. Always operate the generator outdoors in a well-ventilated area.
Drain the fuel tank and carburetor, change the oil, clean the generator, and store it in a dry, covered location. Disconnect the battery to prevent discharge.