Clarke 7614058 CSA20FBT 20 Tonne Hydraulic Instructions

To set up the Clarke 7614058 CSA20FBT hydraulic press, ensure it is placed on a stable, level surface. Check all components are securely fitted and the hydraulic fluid is at the recommended level.
To bleed the hydraulic system, slowly open the release valve and pump the handle several times to remove any trapped air. Close the valve and test the press for smooth operation.
Check for air in the hydraulic system, ensure there are no leaks, and verify that the hydraulic fluid is at the correct level. Inspect the seals and hoses for any signs of wear or damage.
It is recommended to change the hydraulic fluid every 12 months or after approximately 500 hours of operation to maintain optimal performance.
Regularly inspect and clean the press, check and tighten bolts and connections, and ensure the hydraulic fluid is at the correct level. Replace any worn or damaged components promptly.
To test the pressure gauge, use a calibrated gauge to compare readings while applying a load. If discrepancies are found, the gauge may need calibration or replacement.
Check for any obstructions in the hydraulic system and ensure the oil level is adequate. Lubricate the pivot points and check for any signs of wear or damage in the pump mechanism.
Yes, the Clarke 7614058 CSA20FBT can be used for bending operations. Ensure to use appropriate bending attachments and never exceed the press's capacity.
Always wear safety goggles and gloves, ensure the workpiece is securely positioned, and never stand directly in front of the press during operation. Regularly inspect the press for any signs of wear or damage.
Maintain clean hydraulic fluid, avoid overloading the press, and regularly inspect and replace seals as needed. Store the press in a clean, dry environment to prevent contamination.