Clarke 7230695 PSV6A 400W Folding Base Float Swtich Instructions

To install the Clarke PSV6A pump, first ensure the power is switched off. Place the pump on a stable, flat surface. Connect the float switch to the pump's designated socket, and ensure the cable is not kinked or twisted. Secure the base and ensure it is fully submerged for optimal performance.
Check if the power supply is connected and the switch is turned on. Inspect the float switch for any obstructions or damage. Ensure the pump is not clogged with debris and the impeller is free to rotate.
Regularly clean the pump to remove any debris or sediment. Inspect the float switch and cable for wear and tear. Lubricate moving parts if necessary and store the pump in a dry place when not in use.
The Clarke PSV6A pump is designed to handle water temperatures up to 35°C. Operating above this temperature may cause damage to the pump.
Adjust the float switch by sliding the float along the cable to set the desired activation level. Ensure that the float has enough range to move freely without obstruction.
Check if the float switch is stuck or obstructed. Ensure the switch is properly connected and the pump is not set to manual mode. Adjust the float to ensure it can rise and fall freely.
The Clarke PSV6A is not recommended for saltwater use as it may cause corrosion. Use in freshwater applications only to ensure longevity.
The maximum lift height of the Clarke PSV6A pump is approximately 8 meters, making it suitable for most residential and light commercial applications.
Ensure that the pump is securely mounted and placed on a stable surface. Check for debris in the impeller or housing. Tighten any loose fittings and ensure the float switch is not vibrating against the pump or other objects.
Always disconnect the pump from the power supply before performing maintenance. Avoid running the pump dry. Ensure all connections are secure and free from moisture. Use the pump only for its intended purpose and adhere to all manufacturer guidelines.