The Clarke 7140671 PW80A Petrol Driven Water Pump is a robust and efficient solution designed for high-capacity water transfer tasks. It features a powerful 6.5 HP petrol engine, ensuring reliable performance in various demanding environments. The pump is capable of delivering a maximum flow rate of 1000 liters per minute, making it ideal for agricultural, industrial, or large-scale domestic applications. Equipped with a 3-inch inlet and outlet, it facilitates quick and efficient water movement, reducing operational downtime. The pump's durable construction includes a sturdy cast iron impeller and volute, enhancing its longevity and resistance to wear. Engineered for portability, the Clarke PW80A comes with a protective steel frame that provides stability during operation and ease of transportation. Its compact design, combined with a manageable weight, allows for convenient deployment in remote locations or challenging terrains. The pump is equipped with a recoil start mechanism for easy ignition and includes an integrated oil alert system to prevent damage from low oil levels, thereby ensuring user safety and extending the engine's lifespan. Additionally, the Clarke 7140671 PW80A is designed for straightforward maintenance, with accessible components that facilitate regular servicing and repairs. Its efficient fuel consumption and robust performance make it a cost-effective choice for users requiring a dependable water transfer solution.

Clarke 7140671 PW80A Petrol Driven Water Pump F.A.Q.

How do I start the Clarke 7140671 PW80A Petrol Driven Water Pump?

To start the Clarke 7140671 PW80A, ensure that the fuel valve is open, the choke is set to the closed position, and the ignition switch is turned on. Pull the starter cord gently until resistance is felt, then pull sharply to start the engine.

What type of fuel should be used for the Clarke 7140671 PW80A?

Use clean, fresh unleaded petrol with an octane rating of 86 or higher. Avoid using ethanol-blended fuels as they can cause starting and running problems.

How often should I change the oil in the Clarke 7140671 PW80A water pump?

It is recommended to change the oil every 20 hours of operation or at the start of each season. Use SAE 10W-30 oil for best performance.

What should I do if the water pump is not priming?

Check if the suction hose and strainer are clear of obstructions. Ensure all connections are airtight and fill the pump casing with water to help initiate priming.

How do I maintain the air filter on the Clarke 7140671 PW80A?

Clean the air filter every 25 hours of use or more frequently in dusty conditions. Remove the filter, wash it in warm soapy water, rinse, and allow it to dry completely before reinstalling.

What are the common causes of engine overheating in the Clarke 7140671 PW80A?

Common causes include a dirty air filter, low oil level, or a blocked cooling air intake. Ensure regular maintenance and check the cooling system for any obstructions.

How can I troubleshoot if the engine won't start?

Check the fuel level, ensure the spark plug is clean and properly connected, and verify the ignition switch is in the 'on' position. Additionally, inspect for any fuel line blockages.

How should I store the Clarke 7140671 PW80A during the off-season?

Drain the fuel system completely, change the oil, clean the pump thoroughly, and store it in a dry place. Cover the pump to prevent dust accumulation.

What is the recommended procedure for cleaning the pump after use?

Flush the pump with clean water to remove any debris or chemicals. Run the pump with fresh water for a few minutes, then drain and dry it before storage.

How do I check and adjust the spark plug gap on the Clarke 7140671 PW80A?

Remove the spark plug and use a feeler gauge to check the gap, which should be set to 0.7-0.8 mm. Adjust the gap by gently bending the side electrode as needed.