Clarke 7140651 PW50A Petrol Engine Driven 2 Inch Instructions
![Clarke 7140651 PW50A Petrol Engine Driven 2 Inch Pump manual cover](/images/xmyPLsJucdyLYExxyTbIrPAV/thumbs/thumb175x175.webp)
To start the Clarke 7140651 PW50A pump, ensure the fuel valve is open, set the choke to the closed position, turn the engine switch to 'ON', and pull the starter rope with a firm, steady motion. Once the engine starts, gradually open the choke.
The recommended maintenance schedule includes checking the oil level before each use, replacing the oil every 50 hours of operation, cleaning the air filter every 25 hours, and inspecting the spark plug every 100 hours.
If the pump doesn't start, check the fuel level, ensure the spark plug is clean and properly connected, verify the air filter is clean, and ensure all switches are in the correct position.
Use SAE 10W-30 oil for optimal performance in the Clarke 7140651 PW50A pump. Ensure the oil is suitable for 4-stroke engines.
For storage, drain the fuel tank and carburetor, change the oil, clean the pump, and store it in a dry, well-ventilated place. Cover the pump to protect it from dust and moisture.
Ensure the suction hose is airtight and submerged in water, check for blockages, and ensure the pump casing is filled with water to create a vacuum for priming.
To change the spark plug, disconnect the spark plug cap, remove the old spark plug using a spark plug wrench, check the gap on the new plug, and install it by hand, ensuring it is tight. Reconnect the spark plug cap.
The maximum suction lift for the Clarke 7140651 PW50A pump is approximately 7 meters. Ensure the suction hose is as short and straight as possible to optimize performance.
The air filter should be inspected and cleaned every 25 hours of operation and replaced if it is damaged or excessively dirty.
Always operate the pump outdoors in a well-ventilated area, wear appropriate protective gear, avoid contact with hot surfaces, and keep flammable materials away from the engine.