Clarke 7140640 PW2 Petrol Driven Water Instructions
![Clarke 7140640 PW2 Petrol Driven Water Pump manual cover](/images/nDwzmnPOzNWUbOuvnjRBYliL/thumbs/thumb175x175.webp)
To start the Clarke 7140640 PW2 water pump, ensure that the fuel tank is filled with unleaded petrol. Turn the fuel valve to the 'ON' position, set the choke to the closed position if the engine is cold, switch the engine control to 'ON', and then pull the starter cord briskly. Once the engine starts, gradually move the choke to the open position.
If the pump does not prime, check for air leaks in the suction hose and connections, ensure that the strainer is not clogged, and confirm that the pump casing is filled with water. Make sure the suction lift is within the pump's capability and that the hoses are not damaged.
It is recommended to change the engine oil after the first 20 hours of operation, and then every 50 hours thereafter. Use SAE 10W-30 oil for optimal performance. Ensure the engine is off and cool before changing the oil.
Regular maintenance includes checking and cleaning the air filter, inspecting the spark plug, checking fuel lines for leaks, and cleaning the pump casing. Always store the pump in a dry, protected location and run it periodically to ensure all components remain operational.
Use fresh, unleaded petrol with an octane rating of 86 or higher. Avoid using fuel with more than 10% ethanol content to prevent damage to the engine components.
If the engine won't start, check the fuel level and quality, ensure the spark plug is clean and properly gapped, verify the air filter is clean, and make sure the engine switch is set to 'ON'. Inspect the fuel lines for clogs and ensure the choke is set correctly for starting conditions.
No, the Clarke 7140640 PW2 water pump is designed for water only. Using it to pump chemicals or other corrosive fluids can damage the pump components and void the warranty.
To clean the air filter, remove the cover and take out the foam filter element. Wash it in warm, soapy water, rinse thoroughly, and let it dry completely. Lightly oil the filter before reinstalling it to ensure optimal filtration.
The Clarke 7140640 PW2 water pump has a maximum suction lift capability of 7 meters. Ensure that the suction hose is airtight to maintain this performance level.
To winterize the pump, drain all fuel from the tank and carburetor to prevent gumming. Remove the spark plug and add a few drops of oil into the cylinder, then pull the starter gently to distribute the oil. Store the pump in a dry, cool place.