To start the pump, ensure that the power supply is connected, and turn the power switch to the "ON" position. To stop the pump, turn the power switch to the "OFF" position, and disconnect the power supply if necessary.
The oil should be changed every 500 hours of operation or every 6 months, whichever comes first. Regular oil changes ensure optimal performance and longevity of the pump.
Use high-quality vacuum pump oil that is compatible with rotary vane pumps, such as ISO VG 32 grade oil. Always refer to the manufacturer's specifications for the best results.
Check for any visible leaks in the system, ensure that the oil level is adequate, and inspect the pump inlet for blockages. If the problem persists, consult the user manual or contact technical support.
Excessive noise could be caused by worn bearings, low oil levels, or foreign objects in the pump. Regular maintenance and inspections can help prevent these issues.
While the pump can handle continuous operation, it's recommended to monitor its temperature and performance during extended use. Ensure proper ventilation and cooling to prevent overheating.
Regularly inspect and clean the air filters, check oil levels, and ensure all connections are tight. Follow the maintenance schedule in the user manual for detailed instructions.
Check the power supply and ensure the pump is properly connected. Inspect the fuse and replace if necessary. If the issue persists, consult the user manual or contact technical support.
Perform a vacuum test by isolating the pump and monitoring the pressure gauge. A steady drop in pressure indicates a leak. Use a leak detection spray or soapy water to identify the source.
Store the pump in a clean, dry location away from direct sunlight and corrosive substances. Ensure it is protected from dust and moisture when not in use.