Clarke 5060205 PTP100 Pressure Test Instructions
![Clarke 5060205 PTP100 Pressure Test Pump manual cover](/images/RWRsQKEPiQTwvuPgfbZyojfc/thumbs/thumb175x175.webp)
To set up the Clarke 5060205 PTP100 Pressure Test Pump, first ensure all components are present. Connect the pump to the appropriate pressure line and secure all fittings. Fill the reservoir with clean hydraulic fluid and prime the pump by operating the handle until fluid is expelled from the outlet.
If the pump fails to build pressure, check for leaks in the system. Ensure all connections are tight and the reservoir is filled with fluid. Inspect the seals and gaskets for wear and replace if necessary. Additionally, ensure the release valve is fully closed.
Regular maintenance should be conducted every three months or after every 50 hours of use, whichever comes first. This includes checking for leaks, inspecting seals, and ensuring the reservoir is filled with clean hydraulic fluid.
It is recommended to use only hydraulic fluid that complies with ISO VG 32 specifications to ensure optimal performance and longevity of the Clarke PTP100 Pressure Test Pump. Using other types of fluid may damage the pump.
The Clarke 5060205 PTP100 Pressure Test Pump is capable of generating up to 1450 psi (100 bar) of pressure. Ensure not to exceed this limit to prevent damage to the pump or connected equipment.
To bleed air from the system, ensure the pump is filled with fluid. Slowly operate the pump handle to expel air through the outlet. Continue until only fluid is seen and all air is removed. Make sure all connections are tight to prevent air ingress.
If you notice a fluid leak, immediately stop using the pump. Check all seals, gaskets, and connections for wear or damage. Replace any faulty components and ensure all fittings are properly tightened before resuming use.
The Clarke PTP100 does not typically require calibration. However, it is crucial to regularly check the accuracy of the pressure gauge and replace it if there are discrepancies.
When not in use, store the Clarke PTP100 in a clean, dry place away from direct sunlight. Ensure the pump is clean and the reservoir is filled with fluid to prevent corrosion. Keep it in its carrying case to protect it from dust and damage.
Always wear appropriate personal protective equipment, such as gloves and safety goggles, while operating the pump. Ensure all connections are secure before building pressure and never exceed the pump's maximum pressure rating. Keep the work area clean and free from hazards.