Clarke 2245250 Boxer 14 150p 400V Belt Driven Air Instructions
![Clarke 2245250 Boxer 14 150p 400V Belt Driven Air Compressor manual cover](/images/QDLfhUoQIsBkryGyYzDhDPhY/thumbs/thumb175x175.webp)
Ensure the compressor is placed on a level surface. Connect the compressor to a 400V power source, and verify that all connections are secure. Fill the oil reservoir with the recommended compressor oil up to the indicated level.
Regular maintenance includes checking the oil level and changing the oil every 500 hours of operation, cleaning or replacing the air filter monthly, and inspecting belts for wear and tension.
Check the power supply and ensure the compressor is connected to a 400V outlet. Inspect the fuse or circuit breaker for any issues. Verify that the pressure switch is operational and the tank is not overpressurized.
Unusual noises may indicate loose components, worn bearings, or lack of lubrication. Inspect the compressor for loose bolts or fittings, check the condition of the bearings, and ensure sufficient oil is in the compressor.
The oil should be changed every 500 hours of operation or as recommended in the user manual. Use the specified compressor oil type for optimal performance.
Turn off the compressor and disconnect it from the power source. Open the drain valve at the bottom of the tank to release any accumulated moisture. Close the valve securely after draining.
Regularly maintain the compressor by keeping the air filter clean, ensuring proper oil levels, and checking for air leaks in hoses and connections. Use the compressor in a well-ventilated area to prevent overheating.
Refer to the user manual for the specific belt tension specifications. Generally, there should be a slight deflection when pressing on the belt with moderate force. Adjust the tensioner if necessary.
Stop the compressor immediately and allow it to cool down. Check for adequate ventilation and ensure the cooling fins are clean. Examine the oil level and replenish if necessary.
Turn off the compressor and disconnect it from the power source. Remove the air filter cover and take out the old filter. Insert a new filter and replace the cover, ensuring it is secured tightly.