Charnwood Bay BX Parts List

To light a fire in the Charnwood Bay BX, ensure the air controls are open, place kindling and paper at the base, and light the paper. Gradually add larger logs once the kindling is burning well.
To clean the glass, use a damp cloth with a bit of ash from the stove or a specialized stove glass cleaner. Avoid abrasive materials to prevent scratching.
Ensure the chimney is not blocked, check that the air vents are open, and verify that the room is well-ventilated. Also, confirm that the stove door is sealing properly.
Annual maintenance includes checking the chimney for blockages, inspecting seals and gaskets, cleaning the stove thoroughly, and servicing any moving parts.
Adjust the primary and secondary air controls based on the type of wood and desired burn rate. Generally, open both controls fully when starting the fire, then adjust as needed for efficient burning.
The Charnwood Bay BX is designed for wood burning. Burning coal may damage the stove and is not recommended unless specified by the manufacturer.
To fix a broken seal, purchase a replacement gasket from a supplier, remove the old seal, clean the groove, and fit the new gasket as per the instructions.
Ensure the stove is loaded with dry, seasoned wood, the air controls are set correctly, and check for any blockages in the flue or chimney that might impede airflow.
Empty the ash pan regularly to prevent ash buildup, ideally before each use or when the ash reaches the air holes at the base of the firebox.
Ensure proper installation, regularly check for leaks, use a fireguard, and always supervise the fire. Install smoke and carbon monoxide detectors in the room.