Campbell Scientific SR50 Instruction Manual
![Campbell Scientific SR50 Sensor manual cover](/images/JGvhQSUAJANHzHYOngSjeViN/thumbs/thumb175x175.webp)
To connect the SR50 sensor to a data logger, use the sensor's cable to connect the appropriate wires to the data logger's input terminals. Refer to the sensor and data logger manuals for specific wiring diagrams and configurations.
The SR50 sensor should be inspected every 6 to 12 months. Check for any physical damage, clean the sensor face with a soft cloth if necessary, and verify that the sensor is securely mounted.
If the SR50 sensor provides incorrect readings, check the wiring connections, ensure that the sensor is properly aligned, and verify that there are no obstructions blocking the sensor's path. Additionally, check for any software configuration errors in the data logger.
Environmental factors such as temperature extremes, high humidity, and strong winds can affect the SR50 sensor's accuracy. It is important to install the sensor in a location that minimizes these effects or apply appropriate corrections in the data analysis.
The SR50 sensor is factory calibrated and typically does not require field calibration. However, if calibration is necessary, use a known reference distance and adjust the sensor settings accordingly. Consult the sensor manual for detailed calibration procedures.
The SR50 sensor supports various data output formats, including SDI-12, RS-232, and RS-485. Select the format that is compatible with your data logging system and configure the sensor accordingly.
Yes, the SR50 sensor is designed to operate in snowy conditions. It uses an ultrasonic pulse to measure distance to the snow surface, making it effective for snow depth measurements. Ensure the sensor face is kept clear of ice buildup for optimal performance.
To update the firmware on the SR50 sensor, connect the sensor to a computer using the appropriate interface and follow the manufacturer's instructions for downloading and installing the firmware update. Ensure that the sensor remains powered throughout the process.
The SR50 sensor typically has a measurement range of 0.5 to 10 meters. This range allows it to be used effectively for a variety of applications, including snow and water level measurements.
To integrate the SR50 sensor with a CR1000 data logger, configure the data logger to read the sensor's output based on the chosen communication protocol. Use LoggerNet or similar software to set up the data logger's program for data acquisition.