Campbell Scientific RAWS-P Instruction Manual

To set up the RAWS-P Weather Station, start by assembling the tripod and mounting the sensors according to the manual. Connect the sensors to the appropriate ports on the data logger. Power the station using the solar panel or an AC connection. Configure the data logger using the LoggerNet software, ensuring that the correct communication settings and measurement parameters are set.
Check all cable connections between the weather station and your computer. Ensure that the correct COM port is selected in the LoggerNet software. Verify that the data logger is powered on and that the baud rate settings match between the logger and LoggerNet.
Regular maintenance includes cleaning the sensors, inspecting the solar panel for debris, and checking all cable connections for wear and tear. It's also important to routinely check the battery voltage and replace the battery if necessary.
Calibration procedures vary by sensor type. Refer to the sensor-specific manual for detailed calibration instructions. Generally, it involves comparing the sensor readings with a reference instrument and making adjustments as needed using the data logger's settings.
Download the latest firmware from the Campbell Scientific website. Connect your data logger to a computer via USB or serial connection, and use the Device Configuration Utility to upload the new firmware. Follow the on-screen instructions to complete the update.
Inaccurate wind speed readings could be caused by obstructions near the anemometer, sensor misalignment, or debris blocking the sensor. Ensure the sensor is mounted according to the guidelines, and clear any obstructions or debris.
To extend battery life, ensure the solar panel is clean and properly positioned. Reduce the data logging frequency and disable any unnecessary sensors or peripherals. Consider upgrading to a higher capacity battery if necessary.
Check the temperature sensor for any physical damage or obstructions. Ensure it is properly shielded from direct sunlight. Re-calibrate the sensor if necessary, and verify that all connections are secure.
Use LoggerNet to download data from the station. Connect the data logger to your computer and use the software's data logger support tools to retrieve the data. Export the data to a CSV file for analysis in Excel or other data analysis software.
First, ensure that the station is powered and that all connections are secure. Check the data logger's memory capacity and clear old data if necessary. Verify that the data logging schedule is correctly configured in the LoggerNet software.