To set up the HydroSense CD620, begin by installing the batteries in the display unit. Connect the probe to the display unit, power on the device, and calibrate it according to the soil type you are working with. Refer to the user manual for detailed calibration steps.
First, ensure that the batteries are correctly installed and fully charged. Check the battery contacts for any corrosion or dirt. If the problem persists, try replacing the batteries or contact Campbell Scientific support for further assistance.
The HydroSense CD620 provides soil moisture content as volumetric water content (VWC). To interpret the readings, compare them against the known field capacity and wilting point of your soil type. This will help you determine irrigation needs.
The HydroSense CD620 can be used in saline soils, but the readings may be affected by the soil's electrical conductivity. It is recommended to perform a site-specific calibration to improve accuracy in saline conditions.
Calibration frequency depends on the accuracy requirements and environmental conditions. Generally, recalibration is recommended if there is a significant change in soil type or if the device has been exposed to extreme environmental conditions.
Regular maintenance includes cleaning the probe after each use, checking for physical damage, and ensuring the batteries are charged. Periodically verify the calibration and store the device in a dry, cool place when not in use.
The HydroSense CD620 is designed for spot measurements rather than continuous monitoring. For continuous data logging, consider integrating it with a compatible data logger or explore other Campbell Scientific solutions designed for continuous monitoring.
If readings appear inaccurate, check the probe for dirt or damage, ensure it is inserted fully into the soil, and verify the calibration settings. If the issue persists, recalibrate or contact support for further troubleshooting.
To change the measurement units, access the settings menu on the display unit. Navigate to the units section and select the desired measurement unit (e.g., inches or centimeters). Refer to the user manual for detailed instructions.
Store the HydroSense CD620 in a dry, cool environment. Remove the batteries if the device will not be used for an extended period to prevent battery leakage. Clean the probe and ensure all parts are dry before storage.