Campbell Scientific 27106T Product Manual

Campbell Scientific 27106T Sensor manual cover
Pages 21
Year 0
Language(s)
English en

Campbell Scientific 27106T Sensor Specification

The Campbell Scientific 27106T Sensor is a high-precision wind speed and direction sensor designed for demanding meteorological applications. This sensor features a robust construction with stainless steel and anodized aluminum materials, ensuring durability and resistance to harsh environmental conditions. It operates efficiently in a wide temperature range from -30°C to 70°C, making it suitable for various climates. The sensor offers a wind speed measurement range of 0 to 75 m/s with an accuracy of ±0.1 m/s or 1% of reading, whichever is greater, and a wind direction range of 0° to 360° with an accuracy of ±2°. Its low threshold of 0.3 m/s ensures accurate readings at low wind speeds. The 27106T utilizes a three-cup anemometer for wind speed and a vane for wind direction, both of which are designed to minimize the effects of turbulence and mechanical inertia. It provides an analog output of 0-5000 mV for wind speed and a 10 kΩ potentiometric output for wind direction, allowing for seamless integration with Campbell Scientific dataloggers and other data acquisition systems. The sensor's compact design and lightweight build facilitate easy installation on a variety of masts and structures. It requires minimal maintenance due to its sealed bearings and corrosion-resistant components. Overall, the Campbell Scientific 27106T Sensor is a reliable and precise solution for meteorological monitoring, offering high performance and ease of use in diverse field conditions.

Campbell Scientific 27106T Sensor F.A.Q.

How do I connect the Campbell Scientific 27106T Sensor to a data logger?

To connect the 27106T Sensor to a data logger, attach the sensor's cable to the logger's input ports according to the wiring diagram provided in the sensor's manual. Ensure that all connections are secure and that the logger is configured to read the sensor's output signal.

What is the best way to calibrate the 27106T Sensor?

Calibration of the 27106T Sensor should be done using a precision wind tunnel or at a site with a reference sensor. Follow the calibration instructions in the manual to adjust for any discrepancies between the sensor output and the known wind speed values.

How can I troubleshoot inconsistent readings from the 27106T Sensor?

Check for loose connections, inspect the sensor for physical damage, and ensure the sensor is clean and free from obstructions. Verify that the data logger is configured correctly and that the power supply is stable.

What maintenance is required for the Campbell Scientific 27106T Sensor?

Regular maintenance includes cleaning the sensor to remove dust and debris, checking cable integrity, and performing periodic calibrations to ensure accurate readings.

How should the 27106T Sensor be mounted for optimal performance?

Mount the sensor at a height and location where it is free from obstructions and turbulence. Use a sturdy mast or pole and secure the sensor according to the installation guidelines in the manual.

Can the 27106T Sensor be used in harsh weather conditions?

Yes, the 27106T Sensor is designed for outdoor use and can withstand harsh weather conditions, including rain and high winds. However, regular maintenance is recommended to ensure longevity.

What are the common causes of sensor failure for the 27106T?

Common causes of sensor failure include physical damage, exposure to extreme conditions beyond its rated limits, electrical surges, and improper installation.

How do I verify the accuracy of the 27106T Sensor readings?

Compare the sensor readings with a calibrated reference sensor or perform a field calibration using a known wind speed source. Regular checks and calibration are recommended for accuracy.

What should I do if the 27106T Sensor is not responding?

First, check all power and data connections. Inspect the sensor and cables for physical damage. If issues persist, consult the troubleshooting section of the manual or contact technical support.

Is there a specific software needed to operate the 27106T Sensor?

The 27106T Sensor can be operated using Campbell Scientific’s data loggers with compatible software such as LoggerNet for data collection and analysis. Ensure your software version supports the sensor model.