![Bostitch T50S2 Stapler manual cover](/images/lOvnzvEPMluaIZppITPdsWgg/thumbs/thumb175x175.webp)
To load staples, ensure the stapler is disconnected from the air supply. Pull back the magazine latch, insert the staples with the points facing down, and push the magazine closed until it clicks.
The Bostitch T50S2 is designed to use 16-gauge staples, specifically Bostitch S2 staples, ranging from 1/2-inch to 2-inch in length.
First, disconnect the stapler from the air supply. Open the magazine and remove any stuck staples. Clean the magazine and ensure it's well-lubricated. Reassemble and test with proper staples.
Regularly check for air leaks, clean the magazine and feeder, and apply pneumatic tool oil to the air inlet every 8 hours of use to ensure optimal performance.
Yes, the T50S2 has a depth adjustment feature. Locate the depth adjustment knob near the trigger and rotate it to adjust the staple depth according to your needs.
Ensure the stapler is properly connected to a functioning air compressor and there is sufficient air pressure (70-120 psi). Check for jams and confirm that the trigger safety is engaged.
Always wear safety goggles, disconnect the air supply when not in use, and never point the stapler at yourself or others. Keep fingers away from the trigger when loading staples.
Disconnect the stapler from the air supply, open the magazine, and remove the jammed staple using pliers. Clean the area and reload with the correct staples.
Check all connections and hoses for leaks. Tighten any loose fittings and replace damaged O-rings or seals. Regular maintenance can prevent air leaks.
Disconnect from the air supply, remove all staples, clean the tool, and store it in a cool, dry place. Regularly oil moving parts to prevent rust.