Bostitch N50FN Operation and Maintenance Manual
![Bostitch N50FN Nailer manual cover](/images/GtRnHavxfQoiUaStohBVvNJn/thumbs/thumb175x175.webp)
To load nails, first ensure the nailer is disconnected from the air supply. Slide the magazine release latch and pull back the magazine. Insert a strip of nails into the magazine, ensuring they align with the feed channel. Slide the magazine forward until it locks into place. Reconnect the air supply before use.
If the nailer is not firing, check the air pressure to ensure it is within the recommended range (typically 70-120 PSI). Also, inspect the trigger valve and ensure the nails are properly loaded. If the issue persists, clean the nailer and check for any jammed nails.
It is recommended to apply a few drops of pneumatic tool oil into the air inlet before each use and after every 8 hours of operation. This helps maintain optimal performance and prolongs the tool's lifespan.
The Bostitch N50FN is designed for 15-gauge finish nails. It can accommodate nail lengths ranging from 1-1/4 inches to 2-1/2 inches. Always use Bostitch-approved nails for best performance.
To clear a jam, disconnect the nailer from the air supply. Open the magazine and remove any remaining nails. Use a tool to gently remove the jammed nail from the nosepiece. After clearing, reload nails and reconnect the air supply.
Yes, the Bostitch N50FN is suitable for overhead applications due to its lightweight design. Always ensure proper safety measures, such as wearing eye protection and using a secure ladder, when working overhead.
Regular maintenance includes cleaning the tool after use, lubricating moving parts with pneumatic oil, and checking for any worn or damaged components. Periodically inspect the O-rings and replace them if signs of wear are evident.
To adjust the depth setting, locate the depth adjustment wheel near the trigger. Turn the wheel clockwise to increase the depth or counterclockwise to decrease it. Test on scrap material to ensure the desired depth before proceeding with your project.
If you notice an air leak, inspect the O-rings and seals for damage. Replace any worn or damaged parts. Ensure all fittings are tight and check the air hose connections. If the problem persists, consult the user manual or contact Bostitch support for further assistance.
The Bostitch N50FN requires an air compressor capable of delivering 70-120 PSI. Ensure the compressor has a sufficient airflow rate, typically around 1.9 SCFM at 90 PSI, to maintain consistent performance.